Menu item
[Pulse Length]
[Echo Stretch]
[Echo Average]
[Noise Rejector]
[Wiper]
[Int Rejector]
[Display-Dynamic]
[Display-Curve]
[Color Erase]
1.28.3

How to set custom setups

1. Press the MENU key to open the menu.
2. Use the Cursorpad ( or ) to select [Custom 1 (2 or 3)] and press the ENTER
key.
3. Set menu items.
Note: For easy set up, you can copy the settings of the [Echo] menu (to [Custom
1], [Custom 2], [Custom 3]). Select [Copy] and press the ENTER key. When the
copying is completed, the message "Complete" appears. To erase this message,
press any key.
4. Press the MENU key to close the menu.
Available settings
[Short] or [Long], you can select on 1.5, 1.6, 3.0 and 3.2 nm
ranges.
[Off], [1], [2], [3]
[Off], [1], [2], [Auto]
[Off], [On]
[Off], [1], [2]
[Off], [1], [2], [3]
[Narrow]: Erase weak echoes.
[Normal]: Normal use
[Wide]: Display weaker echoes compared to [Narrow].
[1]: Reduce weak echoes.
[2]: Normal use
[3]: Display weaker echoes in stronger color compared to [1].
0 - 11
Custom menu
1. DESCRIPTION OF OPERATION
See section
1.18
1.22
1.23
1.30
1.31
1.14
1.36
1.37