I0. FLOOR VENT CUTOUT (JOISTS AS SHOWN)
- Check the direction of the floor joists (see illustration).
If the joists" .direction is as shown, locate
the cutout on the "T" as illustrated.
The cutout must miss the floorjoists!
- Cutout may be moved from side to side on line to clear floor _ist.
- Recheck your dimensions and make the cutout.
11. FLOOR VENT CUTOUT
(JOISTS AS SHOWN)
- Check the direction of the floor joists (see illustration).
If the joists' direction is as shown, locate
the cutout on the "T" as illustrated.
The cutout must miss the floor jolstsl
- Cutout may be moved from front to back on line to clear floor joist.
- Recheck your dimensions and make the cutout.
ONTHIS UNE [
k I
,
---_
!
12. WALL
VENT CUTOUT
- Locate the vertical studs in the rear wall. Studs are us_liy
16" (40.64 cm) center to center.
- Will the vent duct be 6" (15.24 cm) round through the wall or 3 1/4" x 10" (8.26 cmx 25,4 cm)
rectangle, vertically iuside the wall?
- See Ducting Instructions
for rear duct inside the wall. NOTE:
Cutout in wall must clear 3 1/4" x
10" (8.26 cmx 25.4 cm) transition elbow.
- Locate the closest stud to your proposed vent hole location.
Use the following chart to figure the
"X" dimension.
See the illustration tbr the other dimeusions.
:
[
VERTICAL DUCT INSIDE WALL
1
6" Round ('f5.24 ¢m)
3%" x 10"
(8.26 em x 25.4 cm)
I
"X" MINIMUM
4" (10.16 era)
6" (15.24cm)
- A 1" (2.54 cm) length of duct must protrude through the wall for connection to the Blower.
111.59 e ml
\