Leak Testing Instructions - Napoleon PRESTIGE II 600 INFRARED Manual

Hide thumbs Also See for PRESTIGE II 600 INFRARED:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Regulator
The following table lists input values for the appliance.
Burner
Orifice Size
I
II
Main
61
65
Main (I.R.)
61
65
Back
56
58
Side
61
66
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.
Gas Category
Orifice Sizes (see above)
Gases / Pressures
Countries
The regulators for both butane and propane must have a rating of at least 1500 g/h. Do not tamper with or
modify regulator. Use only regulators which supply the pressure listed in the table above.

Leak Testing Instructions

WARNING!
A leak test must be performed annually and each time a cylinder is hooked up or if a part
of the gas system is replaced.
WARNING!
Never use an open flame to check for gas leaks. Be certain no sparks or open flames are
in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to
property, serious bodily injury, or death.
Leak testing: This must be done before initial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak Testing
Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommended
by the Napoleon Customer Care department and have the grill inspected by a certified gas installer.
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill inspected
by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
(Gross) Heat Input
(Total)
12.3kW
4.1kW
5.9kW
4.0kW
I
I
3B/P(30)
3+(28-30/37)
I
I
Butane 30mbar
Butane 28-30mbar
Propane 30mbar
Propane 37mbar
DK, FI, NL, NO,
BE, ES, FR, GB, IE,
SE
IT, PT
Gas Usage (Total)
894g/h
298g/h
430g/h
291g/h
I
3B/P(50)
II
Butane 50mbar
Propane 50mbar
DE, AT
5
www.napoleongrills.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents