Safety Information - 3Com 2816-SFP Plus (3C16485) User Manual

3com baseline switch user guide
Table of Contents

Advertisement

S
I
AFETY
NFORMATION
Please read the following safety information carefully
before installing the Baseline Switch 2816-SFP Plus.
WARNING: Installation and removal of the unit must be carried
out by qualified personnel only.
If installing the Switch unit in a stack with other units, the
Switch unit must be installed below the narrower units and
above the deeper units.
The unit must be connected to an earthed (grounded) outlet
to comply with international safety standards.
Do not connect the unit to an A.C. outlet (power supply)
without an earth (ground) connection.
The appliance coupler (the connector to the unit and not the
wall plug) must have a configuration for mating with an
EN60320/IEC320 appliance inlet.
The socket outlet must be near to the unit and easily
accessible. You can only remove power from the unit by
disconnecting the power cord from the outlet.
This unit operates under SELV (Safety Extra Low Voltage)
conditions according to IEC 60. The conditions are only
maintained if the equipment to which it is connected also
operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT
are of IT type, this unit must be powered by 230 V (2P+T) via an
isolation transformer ratio 1:1, with the secondary connection
point labelled Neutral, connected directly to earth (ground).
Impédance à la terre
supplies. If your supplies
Power Cord Set
This must be approved for the country where it will be used.
U.S.A. and
The cord set must be UL-approved and CSA certified.
Canada
The minimum specifications for the flexible cord are:
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least
10 A.
The attachment plug must be an earth-grounding type
with a NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A,
250 V) configuration.
Denmark
The supply plug must comply with Section 107-2-D1, Stan-
dard DK2-1a or DK2-5a.
Switzerland
The supply plug must comply with SEV/ASE 1011.
UK
The supply plug must comply with BS1363 (3-pin 13-amp)
and be fitted with a 5 A fuse which complies with
BS1362.
The mains cord must be <HAR> or <BASEC> marked and
be of type HO3VVF3GO.75 (minimum).
Europe
The supply plug must comply with CEE7/7 ("SCHUKO")
The mains cord must be <HAR> or <BASEC> marked and
be of type HO3VVF3GO.75 (minimum).
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dua 1648-5aaa02Baseline 28163c16485

Table of Contents