4. Troubleshooting

4.2. Service Inspection Mode

Press the 'Heavy' + 'Delicate' + 'Power' buttons at the same time for two seconds to enter Service Inspection Mode.
All LEDs are displayed for the first two seconds and then Software-Ver. It will be indicated Binary Code using 'Wash + Dry + Clean + Child Lock' LED.
You can change the mode by pressing the Normal button once more. If press the Normal button in any mode, mode will be changed to next mode.
If 'Heavy + Quick' LED, 'Heavy' LED or 'Heavy + Delicate + Quick' LED error occur, enter the Service Inspection Mode after resolving problem.
Service Inspection Mode is described in the following table. When you activate this inspection mode, the door must be closed.
Mode
Display
No.1
'Quick' LED
No.2
'Delicate' LED
No.3
'Delicate' + 'Quick' LED
No.4
'Heavy' + 'Quick' LED
4-3
Related Parts
Symptoms (LED Blinking)
Inlet Valve
Water Supply Error
Flow Meter
Low Level Water Error
Low Level Sensor
'Normal' + 'Heavy' + 'Delicate' LED
Circulation Motor
A nozzle does not inject water.
Circulation Motor
Heater Error
Heater
Thermistor
Fan Motor
The Fan Motor does not work.
Dispensor
Note
If Door is open, 'Delicate' + 'Quick' LED will blink.
Water is supplying after low level S/W is detected. If low level S/W is high,
Draining at first.
If water is not supplied, Water Supply Error ('Quick' LED) will blink.
When water level is low after water is supplied, Low Level Water Error
('Normal' + 'Heavy' + 'Quick' LED) will blink.
When Turbidity problem is detected after water is supplied, 'Normal' +
'Heavy' + 'Delicate' LED will blink.
If all functions in this mode are completed, 'Wash' LED will blink.
If Low Level S/W is detected before Circulation Motor is operating, 'Sanitize'
LED will blink.
If Low Level S/W is detected before Circulation Motor is operating, 'Sanitize'
LED will blink.
Circulation Motor and Heater will be operated.
When the temperature is 60˚C or above, the heater is turned off and 'Wash'
LED will blink.
If Heater or Thermistor have problems, the Heater Error ('Heavy' + Delicate'
LED) will blink.
Dispenser will operate during 2 minutes and 10 seconds only one time.
Operate Vent Motor and check whether Rinse aid is filled.
If there is not rinse in Dispenser, Rinse Refilled light is ON.