Digimerge VCD304161 Installation And User Manual page 16

Vcd 300 series 4/8/16 channel network dvr
Table of Contents

Advertisement

2.3.1.
VIDEO-IN
Connect the BNC plug of the camera cable to the corresponding channel number's image input BNC plate,
which is on the rear panel.
Note
Camera Input voltage level is 1Vp-p±10%.
2.3.2.
LOOP OUT
Use to apply the video camera input to other devices. Without using a video distributor, the same image can
be connected to the camera input of other products. (Not applicable)
2.3.3.
MON OUT
Connect the BNC cable of the monitor to MON OUT BNC cable of the rear panel.
2.3.4.
SPOT OUT
The spot monitor can only be used to display input images in automatic interval (switcher) mode. Refer to
"Settings" for automatic interval time setting on the spot monitor.
2.3.5.
S-Video Output
One additional main monitor can be installed by using the S-Video output. Use the S-Video cable to connect
the VCD with the monitor, which has S-Video Input.
2.3.6.
Select NTSC / PAL
Turn off the power on the VCD series and select the NTSC/PAL switch correctly. Then turn on the power
again.
2.3.7.
Audio In
Connect an Audio Input Device.
Note
Input voltage of audio input device is line level.
Use of an audio output device with an amplifier is recommended.
2.3.8.
Audio Out
Connect an Audio Output Device
Note
Use of an audio output device with an amplifier is recommended
2.3.9.
ALARM/SENSOR/RS-485
Connect sensor (dry contact type). Separate the terminal block and wire all devices to desired pins before
connecting the terminal block again. Connect each ground (GND) line to "G" pins.
Note
Supports both N/O (Normal Open) and N/C (Normal Close). If connected sensor is not functioning, ensure
wiring is correct.
Connect various alarm devices controlled by relay output. The VCD series supports RS-485 for P/T/Z
control.
7