OPERATING INSTRUCTIONS
NOTE: there will a 10 second delay for the flame
adjustment when the stove is turned on.
• When Set Temp. is 3° F or higher than Room Temp.,
flame height will be on High.
• When Set Temp. is 2° F higher than Room Temp., flame
height will be on Medium.
• When Set Temp. is 1° F higher than Room Temp., flame
height will be on Low.
• When Set Temp. is equal to Room Temp., flame height
does not change (stays on low).
• When Set Temp. is lower than Room Temp., the stove
will be shut off.
• When Set Temp. is 1° F higher than Room Temp.,
again the flame height will be on Low.
• The fan speed follows the flame height, if the fan is
turned on.
To exit Smart Mode
thermostat and shut off the stove;
®
• Push and hold the THERMO buttons for 3 seconds, Or
• Press the OFF button, Or
• Slide down on the arrow buttons.
To shut off the Smart Mode
to regular thermostat mode, press and hold the THERMO
button and the ON/UP button at the same time for 3 sec-
onds again.
Blower Speed Control
Figure 67
NOTE: Blower will only work with flame on.
The blower speed control function is used to adjust the
speed of the blower connected to
the Signature Command System.
There are four speed levels, Off,
Low, Medium, High.
• Press the FAN button to enter
the blower speed control mode.
The fan icon will start flashing.
• Press the ON/up and OFF/down
button to increase/decrease the
blower speed.
• Press the fan button again to
confirm the speed setting. If the
stove is on, the blower speed
will take effect right away; if the
stove is off, the receiver will remember this setting and
the blower is still off (see blower On Delay and Off De-
lay in the next section).
• After the signal is sent, the ON/up and OFF/down but-
tons become flame height controller again.
• When the fan button is flashing, slide up and down on
the arrow buttons will turn the blower speed to High or
Off directly without pressing the fan button again to con-
firm.
4242
thermostat option and return
®
Figure 67
FP2655
blower speed control
Stardance
• If the blower is turned on using the FAN button, the
blower speed will adjust automatically when using
Smart Mode
thermostat (See Smart Mode
®
section).
Blower On Delay Time and Off Delay Time Setup
Figure 68
• Hold the FAN button for 3 seconds until two numbers
appear on the LCD screen. The left number is blow-
er On Delay and the right number is blower Off Delay
Time.
• When the first number is flashing, use the ON/up button
to set the desired On Delay Time from 0 to 15 min.
• Press the OFF/down button to jump to the Off Delay
Time setup.
• When the second number is flashing, use the ON/up
button again to set the desired Off Delay Time from 0
to 15 min.
• Press the OFF/down button again to finish the setup
and the new settings will be transmitted to the receiver.
• The default settings are 5 minutes for the On Delay
Time and 8 minutes for the Off Delay Time, as shown.
Figure 68
FP2656
blower delay setup
Direct Vent Gas Heater
®
thermostat
®
20306760

Hide quick links: