Specification - Master AC 14 EHP Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 28
GB
Cooling capacity *
Heating capacity *
Power/Ampere consumption for cooling *
Power/Ampere consumption for heating *
Air volume
Humidity removal capacity *
Recommended room size
Power supply
Compressor
Refrigerant
Fan speed
Zegar
Working temperature:
- Cooling:
- Heating:
Connection tube
Net Weight
Dimension
REMARK:
1.
The data marked with '*' may vary for technical reasons: for greater precision, please refer to the rating label placed at the back of the unit.
2.
Measuring condition for above is: Cooling DB 27 C, WB 19 C, Heating - DB 20 C, WB 12 C
BEFORE USE
!
OGÓLNE RODKI OSTRO NO CI
!
ONLY USE IN THE UPRIGHT POSITION ON A FLAT
LEVEL SURFACE AND AT LEAST 50cm FROM ANY
OBJECTS (Fig 1 & 4).
!
DO NOT PLACE OBJECTS ON THE UNIT OR
RESTRICT AIR INLET / OUTLET (FIG. 2).
!
CLOSELY SUPERVISE ANY CHILDREN AND PETS
WHEN UNIT IS IN USE.
!
FOR INDOOR USE ONLY.
!
SWITCH OFF AND UNPLUG WHEN NOT IN USE.
!
DO NOT USE IN HUMID OR WET ENVIRONMENTS
(FIG 3)
!
DO NOT PULL THE UNIT ALONG BY THE CORD. DO
NOT PULL THE UNIT ALONG BY THE CORD.
FOR MAXIMUM EFFICIENCY
!
Close doors and windows
!
! Keep curtains of blinds closed during the sunniest part of
the day
!
Keep filters clean
!
Once room has reached the desired conditions, reduce
temperature and ventilation settings
PARTS
Front (Fig. 5)
19.
Control panel
20.
Cooling air outlet
21.
Caster
22.
Connection tube
23.
Handle
24.
Exhaust air outlet
Back (Fig. 6)
25.
Filter
26.
Cord hanger
27.
Power Cord
28.
Connection box
29.
Handle of the outdoor unit

SPECIFICATION

Model
AC 14 EHP
3956 W
3310 W
1400 W / 6,2 A
1210 W / 5,4 A
560 m3/h
2,2 l/h
3
80 m
220-240V, ~50Hz
rotary
R410A
3
24h
18 ÷ 32°C
7 ÷ 27°C
3m
42 kg
Indoor unit: 482 x 420 x 750 mm
Outdoor unit: 479 x 299 x 480 mm
30.
Drain hole for heat pump function
31.
Fixing clip
Accessories (Fig. 7)
32.
Active carbon filter
33.
Bracket for mounting outdoor unit
34.
Washer, protection cap for terminal of connection tube
35.
Remote controller
36.
Spanners
INSTALLATION
This product is an air conditioner. It is fitted with an indoor
mobile unit and an outdoor unit that can be rested on the floor or
wall. The two units are connected to each other by a 3 meters
flexible tube. (Fig. 8, 9)
Installation of the outdoor unit.
1.
Firmly screw the bracket to the wall. (Fig. 10)
2.
Hang the outdoor unit. (Fig. 11)
Notice!
1.
The maximum distance for the outdoor unit to the floor
should be within 1.5 M.
2.
To avoid damaging the connection tube, leave the window
ajar.
Disconnecting the indoor & outdoor unit
If you need to disconnect the indoor unit from the outdoor unit (to
place it in a more suitable position), please follow the steps below:
11.
Open the tube connection box situated at the back of the
indoor unit. (Fig.12).
B.
Fixing clip
12.
Disconnect the drain tube.(Fig. 13)
E.
Electrical cable
F.
Refrigerant tube
G.
Drain tube
H.
Refrigerant tube
13.
Disconnect the electrical cable (Fig.13)
14.
Disconnect the refrigerant tubes using the spanners
provided.(fig.13). During this operation, takes extreme care
not to break the refrigerant tubes
15.
Open the fixing clip above the tube connection box.