UX-600MU/MC
FO-1660U/C
2. Description
2-1. Extension board unit
1. Remove the TEL/LIU PWB, control PWB and Power Supply PWB
from this unit, and mount the extension board unit instead.
Before connecting the wiring to the extension board unit, set the
test PWB switches to the fixed position.
2. The setting is as follows.
Cable
TP1
1
CNLIU
TP2
14
TP3
CHECK
TEL/LIU
PWB
A set with a mounted
extension board unit
Connector
CNPN2
QCNW-4723SCZZ
CNTH2
QCNW-4724SCZZ
CNCCD2
QCNW-4725SCZZ
CNMT2
QCNW-4726SCZZ
CNLED2
QCNW-4727SCZZ
CNSP2
QCNW-4728SCZZ
CNCS3
QCNW-4729SCZZ
CNSNS
QCNW-4730SCZZ
CNPW
POWER
SUPPLY
PWB
CNLIUA
JP1
JP2
CHECK
CONTROL
PWB
Cable
Cable color
1. Brown
2. Red
3. Orange
4. Yellow
5. Green
The recording paper sensor (P. E) and the hook switch are operated
by OR of the mechanical unit switch and the test PWB switch. When
performing installation in the machine unit, set the test PWB switches
to the fixed position.
Recording paper
sensor
Hook SW
Recording paper
sensor
Hook SW
* Recording paper: ON
No recording paper: OFF
8 – 2
CNSNS
Connected to (PWB)
RHS
TP2 (TEL/LIU)
DRSNS
TP3 (TEL/LIU)
P.E
TP1 (TEL/LIU)
JP2 (CONTROL)
RBN
PIN
JP1 (CONTROL)
Mechanical unit
Actual operation with mechanical unit
ON/OFF operation
OFF (Photo interrupter
is interrupted.)
ON/OFF operation
ON-HOOK
PWB sensor check
OFF
ON/OFF operation
ON-HOOK
ON/OFF operation
PWB to be tested