VALVE ASSEMBLY REPLACEMENT
Turn the unit off and allow to cool to room temperature.
1. Turn off gas supply
2. Remove the pilot shield.
3. Remove glass crystals, garden stones and log set, if installed.
4. Locate and remove 9 screws to remove the burner tray.
5. Lift burner tray off.
6. Remove 6 screws on valve access cover.
7. Turn off gas supply and remove flex connection at valve.
8. Remove orange EV1 wire connected to the gas valve.
9. Remove green EV2 wire connected to the gas valve.
10. Remove 8 screws securing valve assembly.
11. Lift valve assembly up and out.
12. Remove both yellow/green ground wires from valve and valve bracket.
13. Replace valve assembly gasket if necessary.
14. Rotate HI/LO modulating valve all the way to the left for HI position.
15. Install new valve assembly and reverse steps 11-1.
16. Test gas connections for leaks.