INNER FRAMING DIMENSIONS (REQUIRED)

NOTE:FRAMING MATERIAL NOT SUPPLIED
Vent Location
NOTE: PTO30 - Two (2) ventilation grills are required for all enclosures.
This is to alleviate moisture and allow for air to circulate. Minimum recommended size 20" sq (508 mm²) ea.
Vent Location
Vent Location
NOTE: PTO60 - Four (4) ventilation grills are required for all enclosures.
This is to alleviate moisture and allow for air to circulate. Minimum recommended size 20" sq (508 mm²) ea.
37-15/16" (964mm)
TOP VIEW
37-15/16" (964mm)
SIDE VIEW
66-15/16" (1700mm)
TOP VIEW
66-15/16" (1700mm)
SIDE VIEW
NOTE: Framing materials must be non-combustible
when used within 4" of the unit.
Combustible framing materials may be used
outside the 4" clearance range.
Finishing materials MUST be non-combustible.
Consideration should be given to weather / elements
when choosing framing materials (ie. treated lumber,
steel stud).
Vent Location
8-3/4" (222mm)
END VIEW
Regency Plateau® PTO30-1 Outdoor Gas Fireplace
installation
PTO30
PTO60
Vent Location
Vent Location
8-3/4" (222mm)
END VIEW