Flame Characteristics; Optional Anti Condensation Switch (Models B35Ntre And B35Ptre Only) - Napoleon B35NTE Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

48
9.3

FLAME CHARACTERISTICS

It's important to periodically perform a visual check of the pilot and
EN
burner fl ames. Compare them to the illustrations provided. If any fl ame
appears abnormal call a service person.
9.4

OPTIONAL ANTI CONDENSATION SWITCH (MODELS B35NTRE AND B35PTRE ONLY)

This appliance has the option to change from an electronic intermittent pilot ignition (IPI) to a standing pilot for
cold climates. The anti condensation control (standing pilot) is located in the center of the control panel. Using
your fi nger, fl ip the switch up for standing pilot, or down for intermittent pilot ignition.
Turning the ACS switch on will allow the pilot fl ame burning to burn continuously. This mode will minimize the
condensation which forms on the inside of the glass when the main burner is fi rst turned on. It will also help
the fi replace and vent system stabilize more quickly during the colder winter months.
During the warmer winter and summer months, the ACS switch can be turned off to minimize fuel consumption.
W415-1399 / B / 06.17.16
3/8" - 1/2"
(9.5mm - 12.7mm)
FLAME MUST
ENVELOP UPPER
3/8" TO 1/2"
(12.7mm - 9.5mm) OF
THERMOCOUPLE &
THERMOPILE
54.2A
MILLIVOLT
ILLUSTRATED

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B35ntB35ptB35pte

Table of Contents