Automatic Changeover Regulator (Optional); Lp Detector; Operation; Testing - Jayco Eagle Owner's Manual

Folding camping trailer
Hide thumbs Also See for Eagle:
Table of Contents

Advertisement

Automatic Changeover Regulator (Optional)

(FOR OPTIONAL DOUBLE BOTTLES ONLY)
The automatic changeover regulator allows both gas bottles to be turned on simulta-
neously. The arrow on the regulator handle indicates which bottle is in service. When the
indicated bottle in service becomes empty, changeover is automatically accomplished to
commence drawing fuel from the other bottle. At this point, the plastic window will
display a red signal or flag to indicate the condition. The lever should then be flipped
over to indicate service on the other bottle. The first bottle which was depleted can then
be turned off, uncoupled and taken to be refilled without disturbing the RV gas supply.
After refilling, it can be removed and again turned to the "ON" position. When the other
bottle is depleted, the LP gas supply will again be automatically changed back to the first
bottle.

LP DETECTOR

All recreational vehicles with an LP fuel system and propane consuming appliances
require a propane leak detection device for safety protection. Convertor or auxiliary
battery is required to supply 12-volt DC energy to operate leak detector.

Operation

Power ON Warm Up: When power is first applied the yellow LED will flash for three
minutes while the detector is warming up. At the end of that time the LED will turn
Green indicating full operation. If the detector has detected unsafe levels of gas it will
immediately go into alarm.
CAUTION: This detector cannot alarm during the 3 minute warm up cycle.

Testing

WARNING: Test the operation of this detector after the vehicle has been in
storage, before each trip and at least once per week during use.
Simply press the TEST switch any time during the warm up cycle or while in normal
operation. The LED should flash RED and the alarm should sound. Release the switch.
This is the only way you should test your detector. This test feature checks the full
operation of the detector. If this detector does not test properly, return the detector
immediately for repair or replacement.

Alarm

The red LED will flash and the alarm will sound when dangerous levels of gas are
detected. The detector will continue to alarm until the gas clears or the MUTE switch is
pressed.