Installing Bioclip 90; Removing The Cutting Unit - Husqvarna Rider 15V2 Operator's Manual

Hide thumbs Also See for Rider 15V2:
Table of Contents

Advertisement

6. Move the support wheels to their parking
position.
7. Fit the front cover.
8. Secure the collet spring.

Installing BioClip 90

In order to install BioClip 90 the drive belt support
wheel must first be removed.
1. Release the collet spring, see fig above.
2. Remove the locking pin (1) that is located next to
the support wheel.
3. Screw off the nut and washer (2) under the
centre of the support wheel. Remove the screw
and support wheel.
4. Fit the cutting unit according to the instructions
above.

Removing the cutting unit

WARNING!
Wear protective glasses when
removing the cutting unit. The
collet spring which tensions up
the belt can go off and cause
personal injury.
1. Carry out points 1-9 to put the cutting unit in the
service position, see "Service position for the
cutting unit".
2. Remove the bolt (3) and lift off the cutting unit.
30
– English
MAINTENANCE
1
2
1
2
3