Removing The Bioclip Plug - Husqvarna R 214T AWD Operator's Manual

Table of Contents

Advertisement

Assemble the parts in the reverse order.
The blade must be mounted with the angled ends pointing
up towards the cover.
Tightening torque 45-50 Nm (4.5-5 kpm/32-36 lbft).
15mm
WARNING! Wear gloves to protect your
!
hands when working with the blades.
IMPORTANT! Always exercise care and use your common
sense. Avoid all situations which you consider to be beyond
your capability. If you still feel uncertain about operating
procedures after reading these instructions, you should
consult an expert before continuing. Contact an authorised
service workshop.
Always use genuine parts. For more information, see the
"Technical data" section.

Removing the BioClip plug

To change a Combi unit from BioClip function to cutting unit
with rear ejection, remove the BioClip plug located under the
unit with three screws.
Combi 103
1 Put the unit in the service position, see Placing in the
service position.
2 Remove the three screws holding the BioClip plug, and
remove the plug.
3 Tip: Fit three full-thread screws M8x15 mm in the screw
holes to protect the threads.
4 Replace the unit in normal position.
Fit the BioClip plug in the reverse order.
26 –
English
Maintenance
Combi 94
1 Put the unit in the service position, see Service position for
the cutting unit.
2 Loosen the knob and the bolts holding the BioClip plug
and remove the plug.
3 Replace the unit in normal position.

Advertisement

Table of Contents
loading

This manual is also suitable for:

R 214t970 54 22-01

Table of Contents