SECTION 4 - PROGRAMMING

4.1 Programming the GSM 1000 Module

There are several programmable options in the GSM 1000. These options can be accessed and programmed
in two ways: via the GSM 1000 Programmer (optional unit), or via your personal computer (PC) with Hyper
Terminal program. Both methods make a simple connection to the RJ-45 socket on the GSM 1000 module.
Please refer to connection diagram and the appropriate GSM 1000 Programming section below.
Note: Jumper J4 must be on when programming the module. Be sure to remove the jumper when you are
finished programming. Also, be sure to end your programming session with the "0F" command to properly
exit and initialize the new settings.
4.1.1 Using GSM 1000 Programmer
The GSM 1000 Programmer is used to enter the required GSM cellular network parameters into the GSM
1000. If the parameters are not entered correctly, the GSM 1000 will not operate properly.
Connect the BLACK and RED wires of the programming unit to the "-" and "+" terminals of the standby
battery. Next, insert the SIM card to its holder and lock the card holder. Short jumper J4 and connect the
GSM 1000 Programming Unit to RJ45 connector. Please note that GSM 1000 Programming Module has
to be connected to the system before power-up!
Apply power to the whole system after checking all the wiring between the control panel and the GSM 1000
module. After about 10 seconds the LCD display should show the "Enter Password" message. The
password is A1AA55. Enter the password terminating the line with <ENTER>. The Password can be entered
2 times only. After 2 wrong attempts the GSM 1000 unit will lock you out. All data strings have to be
terminated with <ENTER>. . . . . Upper case letters from A to F can be produced by pressing <1 to 6> while
depressing the <SHIFT> button. Please see following chart:
Keys depressed
0 to 9
<SHIFT> + 1
<SHIFT> + 2
<SHIFT> + 3
<SHIFT> + 4
<SHIFT> + 5
<SHIFT> + 6
The next message will be: "Selection:" Enter the number representing the feature you want to program or
change and the <ENTER> at the end. You have to enter a two-digit number for "Selection". If the first number
is 0 0 0 0 0 , the unit will perform EDITing of the options; and if it is 1, it will perform DIAGNOSTICS function.
Options
The following options can be EDITed:
00
Display software version
01
Display PCB revision
02
Set number of Cell error before reporting error to panel
03 - 04 For future use
Ring Detect (EEPROM flag)
05
06 - 07 For future use
08
PIN number
09
'PANIC' phone number
0A - 0D For future use
0E
Return to Selection mode
0F
Exit Programming mode
LCD display
0-9
A
B
C
D
E
F