INSTALLATION
Continued
2. Locate power cord. Remove wire tie or tape
holding plug end of power cord.
3. Power cord has 2 plastic hole bushings
threaded onto it. Route cord's 3-prong plug
through the 1.5" diameter hole in appropriate
floor support bracket.
4. Push first plastic bushing completely through
hole. Squeeze bushing as needed to do this.
5. Install the second plastic bushing into the hole
in the floor support bracket by snapping into
place.
6. Route the 3-prong plug through the 1.5" hole
in fireplace outer casing.
7. Install the first plastic bushing into this hole
by snapping into place.
8. After you have connected to gas supply and
checked your gas connections (see pages 17
through 19), plug power cord into any conve-
nient 3-prong grounded wall receptacle near
fireplace.
For Recessed Installation
If an outlet is not installed in fireplace, install
model GA3555 - Outlet Kit with Cover. This kit
will supply a convenient 3-prong grounded elec-
trical outlet for power. Refer to installation manual
provided with this optional accessory for instruc-
tions on wiring. Note: A qualified installer must
make all electrical connections.
RELOCATING WALL SWITCH
Note: The decorative wall switch plate supplied
is white. The wall switch plate may be painted to
match your decor.
The push-button switch and decorative wall plate
assembly supplied with your fireplace is pre-
mounted at the factory in the lower cavity of the
fireplace. You may relocate this switch/plate as-
sembly to a more convenient location such as the
side of your mantel or directly onto the wall near
the fireplace. To mount the wall switch/plate as-
sembly, you must first cut openings in the mantel
or wall where the switch will be located.
Note: If you choose to relocate the wall switch,
do so before final installation into a mantel or re-
cessing into a wall. If you are installing an op-
tional blower accessory, install it at the same time
you relocate the wall switch.
10
must never be mounted directly
above the fireplace where heat
may damage it. If you relocate
wall switch from lower fireplace
cavity, it must be mounted ei-
ther on side wall of mantel or on
wall to side of fireplace.
For Recessed Installation
If fireplace is to be recessed into a wall (see Built-
In Fireplace Installation, pages 21 and 22), we
recommend mounting wall switch to left side of
fireplace. The wall switch should be mounted ap-
proximately 12" from left edge of fireplace, and
less than 60" from the floor. IMPORTANT: Do
not locate wall switch directly in front of wall stud
- there must be room behind wall board for wires
from switch. If you choose to locate wall switch
to right side of fireplace, the length of the cord
restricts you to less than 6" from right edge of fire-
place and less than 48" from floor.
For Mantel Installation
If fireplace is to be installed into a mantel, (see
Conventional Fireplace Installation, page 20) the
wall switch may be mounted on either side of the
mantel, facing to the side. Do not locate wall switch
anywhere on the front face of the mantel.
lines and wiring when moving floor.
1. Determine the new location for the wall
switch. The wires attached to switch are six
feet long.
2. Remove 2 screws securing plastic wall plate to
bracket in fireplace lower cavity. Save screws.
3. Remove wire tie holding coiled wire attached
to wall switch (see Figure 8).
4. Remove wall switch/plate assembly from
bracket.
Burner
Outlet
Tube
Figure 8 - Relocating Switch and Wall
www.desatech.com
CAUTION: The wall switch
CAUTION: Be careful of gas
Wire
Tie
Gas Control
Valve
Plate
Firebox
Bottom
Switch with
Wall Plate
108117-01K