Operation - DeWalt D27901 Original Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
sucked up from a container it is recom-
mended to deactivate the "Filter
Dedusting" function.
If the maximum liquid level is reached
the appliance will turn off automatically.
In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
After the wet vacuuming: Clean the flat
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.
Clip connection
Illustration
The suction hose is equipped with a clip
system. All C-35/C-DN-35 accessories can
be connected.

Operation

Turning on the Appliance
 Plug in the main plug.
 Switch on the appliance at the main
switch.
Working with electrical power tools
Danger
Risk of injury and damage! The socket out-
let is only for the connection of power tools
to the vacuum cleaner. Any other use of the
socket outlet is not permitted.
 Connect the mains plug of the electric
power tool to the vacuum cleaner.
 Switch on the appliance at the main switch.
Indicator lamp is on; vacuum cleaner is in
the standby mode.
Note: The vacuum cleaner is turned on and
off automatically with the electric power tool.
Note: The vacuum cleaner starts automat-
ically within 0.5 seconds and continues to
run for 15 seconds after the power tool has
being switched off.
Note: Please refer to "Technical specifica-
tions" for the power connection specifica-
tions of the power tools.
Illustration
 Adjust the stepped power tool adaptor
to fit the connection of the electric pow-
er tool.
Illustration
 Remove the elbow from the suction hose.
 Attach the stepped power tool adaptor
to the suction hose.
Illustration
 Connect the adaptor to the electric pow-
er tool.
Filter dedusting
Note: A filter dedusting every 5 to 10 min-
utes will increase the life of the flat folded
filter.
Switch off filter dedusting:
 Push the slide upward.
Switch on filter dedusting:
 Push the slide downward.
Illustration
 Press and hold the switch on the handle
for several seconds while the filter
cleaning is turned on. The flat folded fil-
ter is automatically cleaned through an
air jet (pulsating sound).
Turn off the appliance
 Filter dedusting: Repeatedly press the
button on the handle while the filter
cleaning is turned on.
 Switch off the appliance at the main
switch.
 Pull out the mains plug.
After each operation
 Empty the container.
 Vacuum and wipe the appliance inside
and outside with a damp cloth.
Storing the Appliance
 Wind the mains cable around the cable
holder.
 Place the appliance in a dry room and
secure it from unauthorized use.
– 3
EN
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents