3-4 OTHER CIRCUIT
3-4-1 TELEPHONE IF CIRCUIT (LOGIC UNIT)
The signals from the telephone line (FRONT, J13) are
applied to the ringer detect circuit (C100, C103, C375,
R131, D1, D5, R143, R145, IC48). The detected signals are
applied to the CPU (IC33, pin 73) via "RING" line. The
"HOOKC" signal from the CPU (IC33, pin 72) and the "DP"
signal from IC47 are applied to the hook switch (RL1, RL2)
to off-hook.
Received AF signals from the RX unit pass through the high-
pass filter, de-emphasis and low-pass filter circuits. The fil-
tered AF signal are amplified at IC7 and are then applied to
the network IC (IC46, pin 16) via T6. The output signal from
IC46 are applied to the J13 (FRONT unit).
AF signals from J13 (FRONT unit) are applied to the network
IC (IC46). The output signals from IC46 (pins 8, 9) are
applied the AF amplifier IC (IC1, pin 2) via T8. The signals
pass through the MIC mute switch, the MIC mixer amplifier,
the pre-emphasis circuit, the high-pass filter, limiter amplifi-
er circuit, S-mixer circuit, and splatter filter circuit. The fil-
tered signals are applied to the TX unit.
After off-hook condition, DTMF signal from telephone line is
applied to the decoder IC (IC31) to decode the DTMF signal.
The DTMF signal is applied to the CPU (IC33) via serial sig-
nal line.
The end signal is detected at IC45 and then is applied to the
CPU (IC33). The "HOOKC" signal from the CPU (IC33, pin
72) and the "DP" signal from IC47 are applied to the hook
switch (RL1, RL2) to on-hook.
3-4-2 EEPROM CIRCUIT (LOGIC UNIT)
The detector IC (IC34) detects power supply ON-OFF volt-
age. The signal from IC34 is applied to IC33 (CPU). IC35,
IC36 are reset signal circuit which stabilizes to memory for
the EEPROM (IC37).
EEPROM (IC37) memories clone data and adjust setting
condition data.
3-4-3 TEMPERATURE DETECT CIRCUIT
(LOGIC UNIT)
The temperature detect circuit protects the power amplifier
and power supply circuit from high temperature and stabi-
lizes the output power.
Inside temperature of the PA unit is detected at D1 (VARIS-
TOR unit) and is then applied to the amplifier (PA unit; IC4).
The amplified signal is applied to the CPU (IC33) to analyze
the temperature via IC32.
Inside temperature of the REG unit is detected at D6 (REG
unit) and is then applied to the amplifier(REG unit; IC9). The
amplified signal applied to the CPU (IC33) to analyze the
temperature via IC32.
IC32 selects "PATEMP" or "REGTEMP" signals from the PA
or REG unit.

3-5 POWER SUPPLY CIRCUITS

3-5-1 LOGIC AND REG UNITS VOLTAGE LINES
Line
The voltage from the DC power unit (CHASSIS;
PS 15V
EP1).
The same voltage as the PS 15V line which is
VCC1
controlled by the power switch.
Common 9 V for converted from the VCC1 line
by the M9V regulator circuit (REG unit; IC1, Q8,
M9V
Q9). The voltage is applied to the TX and RX
units.
Common 9 V converted from the VCC1 line by
L9V
the L9V regulator circuit (REG unit; IC2).
Common 5 V converted from the L9V line by the
A5V
A5V regulator circuit (REG unit; IC3).
Common 5 V converted from the L9V line by the
L5V
L5V regulator circuit (LOGIC unit; IC38, Q48,
D43).
Common 5 V converted from the L9V line by the
C5V
C5V regulator circuit (LOGIC unit; IC38, Q45,
D13).
Common 5 V converted from the M9V line by the
TEL5V
TEL5V regulator circuit (LOGIC unit; IC11).
3-5-1 RX UNIT VOLTAGE LINES
Line
Common 5 V converted from the M9V line by the
+5V
+5V regulator circuit (RX unit; IC3).
Common 6 V converted from the M9V line by the
+6V
+6V regulator circuit (RX unit; IC7).
Receive 5 V converted from the R9V line by the
R5V
R5V regulator circuit (RX unit; IC6).
Receive 9 V controlled by the R9V regulator cir-
cuit (RX unit; Q15) using "R9C" signal from IC39
R9V
(LOGIC unit).
The same voltage as the M9V.
V9V
3-5-2 TX UNIT VOLTAGE LINES
Line
Transmit 5 V converted from the M9V line by the
T5V
T5V regulator circuit (TX unit; IC1).
Transmit 6 V converted from the M9V line by the
T6V
T6V regulator circuit (TX unit; IC4).
Common 9 V converted from the M9V line by the
V9V
V9V regulator circuit (TX unit; Q6).
3 - 5