4-2 PLL ADJUSTMENT
ADJUSTMENT
ADJUSTMENT CONDITIONS
TX VCO LOCK
• LCD display
VOLTAGE
1
• Transmitting
RX VCO LOCK
• LCD display
VOLTAGE
1
• Receiving
REFERENCE
1
• Wait for 5 minutes after power ON.
FREQUENCY
• LCD display
Connect an RF power meter or 50 Ω
dummy load to the [TX] antenna con-
nector.
• Transmitting
2
• LCD display
• Receiving
UNIT
: A01 LW TXREF 127
: A01 LW TXREF 127
REAR
: A01 LW TXREF
panel
: A01 LW RXREF
MEASUREMENT
LOCATION
Connect a digital multi
TX
meter or oscilloscope
to check point CP4.
Connect a digital multi
RX
meter or oscilloscope
to check point CP3.
Loosely couple a fre-
quency counter to the
[TX] antenna connec-
tor.
RX
Connect a frequency
counter to check point
CP2.
4 - 4
ADJUSTMENT
VALUE
UNIT
ADJUST
4.0 V
TVCO
4.0 V
RVCO
173.7250 MHz
FRONT
[PRT/BASE]
142.2750 MHz
FRONT
[PRT/BASE]
C17
C17
/[MONI]