D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
Figure 12.1 Intellifi re Ignition Wiring Diagram with Wall Switch or Thermostat
Figure 12.2 Intellifi re Ignition Wiring Diagram with Remote Receiver
28
TRANSFORMER
PLUG IN
BATTERY PACK
WIRE ASSEMBLY
BATTERY PACK
REMOTE
PLUG IN
Heatilator • GBST4336I, GBFL4136I • 2135-900 • 2/08
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
IGNITION MODULE 3 VAC
I
S
3 VAC
WIRES
(TO BROWN)
THERMOSTAT
IGNITION MODULE 3 VAC
TRANSFORMER
3 VAC
PLUG IN
WIRES
(TO BROWN)
INTERMITTENT PILOT IGNITOR
WHITE
ORANGE
GROUND TO
FIREPLACE
CHASSIS
VALVE
INTERMITTENT PILOT IGNITOR
I
S
WHITE
ORANGE
GROUND TO
FIREPLACE
CHASSIS
VALVE