Setup

3. Setup

AC Power

AC Plug

Power Linking

Fuse
Replacement
-6-
Each Ovation E-260WW has an auto-ranging power supply that works with an input voltage
range of 100 to 240 VAC, 50/60 Hz. To determine the power requirements for each Ovation E-
260WW, refer to the label affixed to the product. You can also refer to the
Specifications
chart in this manual.
The listed current rating indicates the maximum current draw during normal operation. For more
information, you may download Sizing Circuit Breakers from the Chauvet website:
www.chauvetprofessional.com.
·
Always connect this product to a protected circuit with an appropriate electrical
ground to avoid the risk of electrocution or fire.
·
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.
The Ovation E-260WW comes with a power input cord terminated with a Neutrik powerCON A
connector on one end and an Edison plug on the other end (U.S. market). If the power input
cord that came with your product has no plug, or if you need to change the Edison plug, use the
table below to wire the new plug.
Connection
AC Live
AC Neutral
AC Ground
The Ovation E-260WW supports power linking. You can power link up to 8 products at
120 V; up to 13 at 208 V; or up to 14 at 230 V.
This product comes with a power input cord. Power linking cables are available from Chauvet
for purchase.
1. Disconnect this product from the power outlet.
2. Using a Phillips-head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove the blown fuse and replace with another fuse of the same type and rating
(T 3.15 A, 250 V).
4. Screw the fuse holder cap back in place and reconnect power.
Make sure to disconnect the product's power cord before replacing a blown fuse. Always
replace the blown fuse with another of the same type and rating.
Wire (U.S.)
Wire (Europe)
Black
White
Green/Yellow
Brown
Yellow or Brass
Blue
Green/Yellow
Ovation E-260WW User Manual Rev. 1
Technical
Screw Color
Silver
Green