Figure 12 Network diagram
If the FCF switch is connected to the converged network adapter (CNA) of the server or storage device,
PFC and DCBX should be configured additionally on the physical interfaces. For information about
configuring PFC and DCBX, see Layer 2—LAN Switching Configuration Guide.
Configuration procedure
This section describes the configurations for VFC interfaces and FIP on the FCF switch.
Configure Switch A:
1.
# Create VSAN 10 and configure Switch A to operate in FCF mode.
<SwitchA> system-view
[SwitchA] fcoe-mode fcf
[SwitchA] vsan 10
[SwitchA-vsan10] quit
# Create interface VFC 1, bind it to interface Ten-GigabitEthernet 1/0/1, and assign it to VSAN
10 as a trunk port.
[SwitchA] interface vfc 1
[SwitchA-Vfc1] bind interface ten-gigabitethernet1/0/1
[SwitchA-Vfc1] port trunk vsan 10
[SwitchA-Vfc1] quit
# Create interface VFC 2, configure it to operate in E mode, bind it to interface
Ten-GigabitEthernet 1/0/2, and assign it to VSAN 10 as a trunk port.
[SwitchA] interface vfc 2
[SwitchA-Vfc2] fc mode e
[SwitchA-Vfc2] bind interface ten-gigabitethernet1/0/2
[SwitchA-Vfc2] port trunk vsan 10
[SwitchA-Vfc2] quit
# Configure interface Ten-GigabitEthernet 1/0/1 to allow VLAN 20.
[SwitchA] interface ten-gigabitethernet1/0/1
[SwitchA-Ten-GigabitEthernet1/0/1] port link-type trunk
[SwitchA-Ten-GigabitEthernet1/0/1] port trunk permit vlan 20
[SwitchA-Ten-GigabitEthernet1/0/1] quit
# Configure interface Ten-GigabitEthernet 1/0/2 to allow VLAN 20.
17