9. If the SOG page is displayed and the tide conditions are slack,
press and hold the Reset button for 3 seconds to accept SOG
as the current speed.
60 5
55
3
10
50
45
15
40
20
35
25
30
10. Alternatively, with the cal factor page displayed use the Trip or
Reset buttons to set the cal factor to your vessel's estimated
current speed.
11. Press the Speed button to display the temperature units page.
S pe e d
12. Press the Speed button to display the temperature calibration
page.
S pe e d
13. Use the Trip or Reset buttons to set the unit to show the current
water temperature.
14. Press the Speed button to display the Timer buzzer page.
S pe e d
15. Use the Trip or Reset buttons to switch the count-up and race
start timer buzzers on and off.
16. To exit the user calibration pages at any time, press and hold the
Depth and Speed buttons simultaneously for 2 seconds.

Intermediate calibration

Intermediate calibration allows you to:
i50 Depth
i50 Speed
Check instrument
Check instrument
software version.
software version.
Check and if necessary
Check the instrument
change the instrument
status (either master or
status (either master or
repeater).
repeater).
Carry out a calibration
run over a measured
distance to ensure
accurate speed
readings.
Checking i50 Depth software version and status
60 5
55
4
50
10
45
15
40
20
35
25
30
+
Alarm
During normal operation:
1. Press and hold the Depth and Alarm buttons simultaneously
for 4 seconds:
The software version is displayed.
2. Press the Depth button to display the instrument status.
Master (transducer connected) or Repeater (No transducer
connected).
3. To change the status:
i.
Press the Offset and Reset buttons simultaneously to enter
adjust mode.
The status flashes when in adjust mode.
ii. Press either Offset or Reset to switch the status between
Master or Repeater.
34
Re s e t
i50 Tridata
Check instrument
software version.
Check and if necessary
change the instrument
status (either master or
repeater).
Carry out a calibration
run over a measured
distance to ensure
accurate speed
readings.
Depth
4. To exit the Intermediate calibration settings at any time, press
and hold the Depth and Alarm buttons simultaneously for 4
seconds.
Checking i50 Speed software version and status
60 5
55
4
50
10
45
15
D12447-1
40
20
35
25
30
+
During normal operation:
1. Press and hold the Speed and Trip buttons simultaneously for
4 seconds:
The software version is displayed.
D12448-1
2. Press the Speed button to display the instrument status.
Master (transducer connected) or Repeater (No transducer
connected).
3. Press the Speed button again to begin speed run calibration.
4. To exit the Intermediate calibration settings at any time, press
and hold the Speed and Trip buttons simultaneously for 4
D12449-1
seconds.
Performing speed run calibration – i50 Speed
This speed calibration involves carrying out up to 2 runs over a
measured distance, to enable a calibration factor to be determined
and applied to your unit. Each run consists of an outward and a
return leg, to minimize the effect of tidal drift when the calibration
factor is determined.
D12450-1
From the Intermediate calibration page:
Note: This procedure is not required if current speed is set to
SOG.
1. Press the Speed button until you reach the Calibration run
length page.
2. Press the Timer and Reset buttons simultaneously to enter
adjust mode.
Time r
In adjust mode the run length flashes.
3. Use the Timer or Reset button to set the run length to the
required value (between 0.25 and 2.50).
4. Press the Timer and Reset buttons simultaneously to commence
the speed run calibration
The calibration status page is displayed. The text at the top of
the page alternates between START 1 and the calibration factor
currently applied.
D12451-1
Time r
5. Start the outward leg of the calibration run and as you pass the
start point, press the Trip button, so the page shows OUTWARD
at the top. As the calibration run proceeds, the displayed value
will change.
Speed
S pe e d
Re s e t
Re s e t
Trip
D12452-1
D12453-1
D12454-1
D12455-1
D12456-1
i50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E70058E70059E70060

Table of Contents