7. Use the Timer or Reset buttons to select the required speed
log units.
8. Press the Speed button to display one of the current speed
pages, if SOG data is available over SeaTalk then the SOG page
is displayed, if SOG data is not available then the cal factor
page is displayed.
S pe e d
S pe e d
9. Press the Timer and Reset buttons simultaneously to switch
between the cal factor and SOG pages.
10. If the SOG page is displayed and the tide conditions are slack,
press and hold the Reset button for 3 seconds to accept SOG
as the current speed.
60 5
55
3
10
50
Re s e t
15
45
40
20
35
25
30
11. Alternatively, with the cal factor page displayed use the Timer
or Reset buttons to set the cal factor to your vessel's estimated
current speed.
12. Press the Speed button to display the temperature units page.
S pe e d
13. Use the Timer or Reset buttons to select the required
temperature units.
14. Press the Speed button to display the temperature calibration
page.
S pe e d
15. Use the Timer or Reset buttons to set the unit to show the
current water temperature.
16. Press the Speed button to display the Timer buzzer page.
S pe e d
17. Use the Timer or Reset buttons to switch the count-up and race
start timer buzzers on and off.
18. To exit the user calibration pages at any time, press and hold the
Speed and Trip buttons simultaneously for 2 seconds.
Calibrating i50 Tridata
1. Press and hold down the Depth and Speed buttons
simultaneously for approximately 2 seconds to display the user
calibration entry page.
60 5
55
2
50
10
45
15
40
20
35
25
30
De pth
Note: The user calibration entry screen will time-out after 8
seconds of inactivity.
Calibrating i50 Tridata depth
From the User calibration entry page:
Getting started
Time r
Re s e t
S pe e d
1. Press the Depth button to display the depth units page.
2. Use the Trip or Reset buttons to select the required depth units.
3. Press the Depth button to display the depth offset page.
4. Use the Trip or Reset buttons to set the required depth offset.
5. Press the Depth button to display the shallow alarm lock page.
D12430-1
6. Use the Trip or Reset buttons to switch the shallow alarm lock
on and off.
D12431-1
7. To exit the user calibration pages at any time, press and hold the
Depth and Speed buttons simultaneously for 2 seconds.
Calibrating i50 Tridata speed
During normal operation:
1. Press the Speed button to display the speed units page.
D12432-1
2. Use the Trip or Reset buttons to set the required speed units.
3. Press the Speed button to display the speed resolution page.
D12434-1
4. Use the Trip or Reset buttons to set the required speed
resolution.
5. Press the Speed button to display the speed log units page.
D12435-1
6. Use the Trip or Reset buttons to select the required speed log
units.
7. Press the Speed button to display one of the current speed
pages, if SOG data is available over SeaTalk then the SOG page
is displayed, if SOG data is not available then the cal factor
page is displayed.
D12436-1
8. Press and hold down the Trip and Reset buttons simultaneously
to switch between the cal factor and SOG pages.
D12438-1
De pth
De pth
De pth
S pe e d
S pe e d
S pe e d
S pe e d
S pe e d
Trip
Re s e t
D12439-1
D12440-1
D12441-1
D12442-1
D12443-1
D12444-1
D12445-1
D12446-1
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E70058E70059E70060

Table of Contents