Removal of the Connecting Duct

Procedure
Step
1. Remove the connecting
duct for humidifying hose
1
Detach the humidifying
hose from the duct unit.
Remove the fixing
2
screw for the duct unit.
3
Lift the right side to
undo the projection and
slide to the left.
Removal Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Humidifying
hose
Alternate up and down
(R10319)
Duct unit
(R10320)
Fixing hole
(R10321)
Projection
Indoor Unit
Points
Preparation
Remove the front grille
according to "Removal of
the Front Grille".
Since inside of the
connecting duct has
projection hooks, shake the
hose up and down to
remove.
Rotate in the same direction
as when assembling for
easy removal.
When assembling, make
sure to insert the projection
into the fixing hole on the
duct unit.