Pioneer avic-d1 Service Manual page 211

Hide thumbs Also See for avic-d1:
Table of Contents

Advertisement

5
3. Inspection screen
1. Connection check
1. Connection check
Illumination signal
Parking brake signal
Reverse gear signal
Car speed signal
Battery voltage
Gyro voltage / sigma
GSENS voltage / sigma
Heading
Pitch
Remote controller
Body key
K mode
[joy stick down] It progresses to the next inspection.
• The status of the item indicated in the above figure will be updated every second.
• When the gyro is in operation, a BEEP sound will be made when the G sensor is activated.
Right: 500Hz, Left: 700Hz. Up: 800Hz, Down: 600Hz
• Conditions for moving on to the next inspection
Illumination status is changing between ON and OFF.
Parking brake status is changing between ON and OFF.
Reverse status is changing between NOR and REV.
Pulse is changing to a value other than 0/0.
All keys on the main body as listed below have been pressed at least once.
"DEST", "INFO", "MEMO", "TRAFFIC"
The value of the gyro changes to right and left at least once for each.
* Until it changes at least once for each, "--" is displayed even when it is OK.
(ex.) When the orientation status is left rotation level 1, it is displayed as below.
Heading
(ex.) When the orientation status is uphill inclination level 1, it is displayed as below.
Pitch
After the value of the gyro changes to right and left at least once for each, the dispersion of the gyro is OK for
five consecutive seconds or longer.
* "CHK" is displayed during continuous inspections.
The voltage of the gyro, and the voltage and temperature of the temperature sensor are OK.
K mode status is changing between ON and OFF.
* K mode is for develop use. K mode status must be "OFF" for normal operation.
Standard value for other items
• GYRO voltage
OK: 2.5±0.15
USABLE: 2.5±0.30
• GYRO variation
OK: Less than 30
• G sensor voltage
OK: 2.0±0.25
USABLE: 2.0±0.40
• G sensor variation
OK: Less than 80
• Only when all the conditions are met, you can move on to the next inspection by the [ ] key on the remote
controller. It should be noted, however, that you will not be able to move on to the next inspection if there is
an error (background color is red) even if the conditions are met.
<Supplemental explanation regarding error display>
Displayed message
No connection to DRAGON
Command error
Unknown error
5
6
<
Left
/ Right
+
Upper
/ Lower
Details of the error
An error when communication with DRAGON cannot be established.
Communication error due to a hardware problem could be the cause.
It is highly possible that the hardware on the DRAGON side is defective.
Time out error for response to BIOS call.
Communication error due to a hardware problem could be the cause.
It is highly possible that the hardware on the DRAGON side is defective.
Error due to unknown reason.
AVIC-D1/UC
6
7
OFF
ON
NOR
0
12.3V
2.450V OK / 1.1 OK
2.050V OK / 1.1 OK
CONST
CONST
--
MENU
OFF
7
8
A
B
C
D
E
F
211
8

Hide quick links: