Outdoor Unit - RK(X)S25/35E2V1B
2.3
Removal of PCB
Procedure
Step
Feature of the main
1
PCB
2
Remove the screw on
the terminal board.
Release the 2 earth
3
terminals.
145
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Terminal
board
You can remove the main
PCB when you disconnect
the lead wires on the
terminal board without
removing the electrical box.
(R7255)
(R7256)
Earth
terminal
(R7257)
SiBE05-722_B
Points
Removal Procedure