Service Check Function; Arc433 Series - Daikin FLXS-BAVMB Service Manual

Floor / ceiling suspended dual type ba-series
Hide thumbs Also See for FLXS-BAVMB:
Table of Contents

Advertisement

SiBE05-722_B

3. Service Check Function

3.1

ARC433 Series

1. When the timer cancel button is held down for 5 seconds, " 00 " indication appears on the
Check Method 1
2. Press the timer cancel button repeatedly until a long beep sounds.
Note:
1. A short beep "pi" and two consecutive beeps "pi pi" indicate non-corresponding codes.
2. To return to the normal mode, hold the timer cancel button down for 5 seconds. When the
Service Diagnosis
temperature display section.
< ARC433 Series >
The code indication changes in the sequence shown below.
No.
Code
00
1
U4
2
F3
3
E6
4
L5
5
A6
6
E5
7
F6
8
C9
9
U0
10
E7
11
remote controller is left untouched for 60 seconds, it also returns to the normal mode.
Timer cancel button
No.
Code
C7
12
H8
13
J3
14
A3
15
A1
16
C4
17
C5
18
H9
19
J6
20
UA
21
A5
22

Service Check Function

(R14195)
No.
Code
H0
23
E1
24
P4
25
L3
26
L4
27
H6
28
H7
29
U2
30
UH
31
EA
32
AH
33
66

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents