Before Use; Installation - Prem-I-Air EH0468 Instruction Manual

3.5kw (12000 btu/hour)
Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT
Installer and Users please note:
These instructions should be read carefully and left with the user of the product
for future reference.

BEFORE USE

Inspect the product including its cable and plug for any signs of damage. If the
product is damaged, DO NOT use it, and contact your supplier immediately. The
appliance contains a refrigerant gas, so must be kept upright at all times. After
unpacking wait 3 hours for the refrigerant gas to stabilise before use.

INSTALLATION

Stand the EH0468 on a firm, flat, level surface.
Connect the exhaust hose as follows: expand a small section of the end, and
screw into the indoor adaptor; then slide the indoor adaptor into the slot at the
back of the unit. Expand a small section of the other end of the hose, and screw
into the fish-tail-shaped adaptor.
Slide the two-part window adaptor to the correct length to fit the window. Close
the window as far as possible to keep the window adaptor in place. Clip the fish-
tail shaped adaptor into the obround aperture in the window adaptor.
Keep the hose as straight as possible, avoid dips where the moisture from the
exhaust air can condense and fill the tube with water. Do not allow the hose to be
crushed.