Server Management Tools Error Messages - Fujitsu PRIMERGY RX600 S4 User Manual

Hide thumbs Also See for PRIMERGY RX600 S4:
Table of Contents

Advertisement

Chapter 8 Operation and Maintenance
iRMC reports sensor status: WARNING
PSU Red

Server Management Tools error messages

The following error messages may appear while executing Server Management Tools. In such cases,
perform the appropriate resolutions. If messages other than the following are displayed, contact an office
listed in the "Contact Information" of "Start Guide".
Write protect error writing drive A.
Abort, Retry, Fail?
Not ready writing drive A.
Abort, Retry, Fail?
ERROR: Fail to create data file.
ERROR: Fail to write 1st CMOS data into data file. nn
ERROR: Fail to write 2nd CMOS data into data file. nn
ERROR: Fail to write ESCD data into the data file. nn
ERROR: Fail to write SEEPROM data into the data
file. nn
ERROR: Fail to open data file.
ERROR: Fail to write 1st CMOS data into system. nn
ERROR: Fail to write 2nd CMOS data into system file.
nn
ERROR: Fail to write ESCD data into system file. nn
ERROR: Fail to write SEEPROM data into system. nn
Other messages
190
table: List of POST error messages
Message
table: List of Server Management Tools error messages
Message
Description
The power supply redundancy has been lost. Replace the relevant
PSU. If the message still appears after the replacement, Power BP
or the baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
The inserted floppy disk is write-protected. Disable the
write-protect, and then press the [R] key.
The floppy disk is not inserted into the floppy disk
drive. Insert the proper floppy disk ("Server
Management Tools" disk), and then press the [R] key.
The following factors may be possibly root causes.
Check the floppy disk condition again.
• The floppy disk is write-protected. Disable the
write-protect and retry.
• The floppy disk is not inserted into the floppy disk
drive. Insert the proper floppy disk, and then retry.
• The floppy disk contains improper data. Create
"Server Management Tools" disk again. If this
occurs while recovering the BIOS information,
configure the information using BIOS Setup Utility.
Then store the BIOS information.
The file to recover the BIOS information does not exist
on this floppy disk. Insert the floppy disk on which the
BIOS information was stored, and then retry.
The following factors may be possibly root causes.
Check the floppy disk condition again.
• The floppy disk is not inserted into the floppy disk
drive. Insert the proper floppy disk, and then retry.
• A different model or an unsupported version of
BIOS information. Insert the proper floppy disk, and
then retry.
• The floppy disk contains improper data. Create
"Server Management Tools" disk again. If this
occurs while recovering BIOS information,
configure the information using BIOS Setup Utility.
Then store the BIOS information.
Contact an office listed in the "Contact Information" of
"Start Guide".