Clicking the mouse does not work on the WebBIOS screen
If clicking the mouse does not work on the WebBIOS screen, check to see whether the keyboard and
mouse are connected properly, and then press any key on the keyboard to try again.
The screen shakes
If a device that produces a strong magnetic field such as a television or speaker is near the display, place
them further away from the display.
The display may also shake if a nearby cell-phone receives a call. Do not use a cell-phone near the
display.
The screen display is distorted
The screen display may be distorted during 3D program execution or the 3D program may terminate
abnormally. If this occurs, set Color quality in screen properties to anything other than True Color (32
bits).
CD/DVD drive unit
Cannot read data
• Check to see whether the CD/DVD is inserted properly. If not, insert the CD/DVD properly with the
label facing up.
• Check to see whether the CD/DVD is not dirty. If it is dirty, wipe it with a soft dry cloth.
• Check to see whether the CD/DVD is scratched or warped. If scratched or damaged, do not use such
a CD/DVD.
The DVD-ROM unit does not operate properly
Check to see whether the internal cable is connected properly. If not, correctly connect the internal
cable.
Optional devices (internal / external)
The unit does not operate properly
• Check to see whether the internal cable is connected properly. If not connected, correctly connect the
internal cable. For the connection location, refer to "6.7.2 Installable 5-inch Internal Devices"
( pg.141).
• For SCSI devices, check to see whether the SCSI-ID and terminator are set correctly. If they are not
set, correctly set the SCSI-ID and terminating resistance.