Appendix A
Specifications
Clean the PXI-8184 with a soft nonmetallic brush. Make sure that the device is
Caution
completely dry and free from contaminants before returning it to service.
Storage Environment
Shock and Vibration
For EMC compliance, operate this device with shielded cabling. In addition, all
Note
covers and filler panels must be installed. Refer to the Declaration of Conformity (DoC)
for this product for any additional regulatory compliance information. To obtain the DoC
for this product, visit
and click the appropriate link in the Certification column.
Safety
NI PXI-8184/8185 User Manual
Ambient temperature range ....................–20 to 65 °C (Tested in
Relative humidity range..........................5% to 95% noncondensing
Operational shock ...................................30 g peak, half-sine, 11 ms pulse
Random vibration
Operating .........................................5 to 500 Hz, 0.3 g
Nonoperating ...................................5 to 500 Hz, 2.4 g
(Tested in accordance with IEC-60068-2-64. Nonoperating test
profile exceeds the requirements of MIL-PRF-28800F, Class B.)
ni.com/certification
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
IEC 61010-1, EN 61010-1
UL 61010-1
CAN/CSA C22.2 No. 61010-1
accordance with IEC-60068-2-1
and IEC-60068-2-2.)
(Tested in accordance with
IEC-60068-2-56.)
(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)
(with solid-state hard drive)
, search by model number or product line,
A-6
rms
rms