National Instruments NI PXI-8221 User Manual
Hide thumbs Also See for NI PXI-8221:

Advertisement

Quick Links

PXI-8221

Advertisement

Table of Contents
loading

Summary of Contents for National Instruments NI PXI-8221

  • Page 1 PXI-8221...
  • Page 2 NI PXI-8184/8185 User Manual NI PXI-8184/8185 User Manual July 2004 Edition Part Number 370836B-01...
  • Page 3 For further support information, refer to the Technical Support and Professional Services appendix. To comment on National Instruments documentation, refer to the National Instruments Web site at ni.com/info and enter the info code feedback. © 2003–2004 National Instruments Corporation. All rights reserved.
  • Page 4 The reader should consult National Instruments if errors are suspected. In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it.
  • Page 5 These classes are known as Class A (for use in industrial-commercial locations only) or Class B (for use in residential or commercial locations). All National Instruments (NI) products are FCC Class A products. Depending on where it is operated, this Class A product could be subject to restrictions in the FCC rules. (In Canada, the Department of Communications (DOC), of Industry Canada, regulates wireless interference in much the same way.) Digital...
  • Page 6: Table Of Contents

    Benefits of PXI ......................1-1 NI PXI-8184/8185 ......................1-1 Description ......................1-1 Modules ......................1-2 Functional Overview ..................1-2 National Instruments Software ..................1-4 Chapter 2 Installation and Configuration Installing the NI PXI-8184/8185 ...................2-1 How to Remove the Controller from the PXI Chassis ........2-4 BIOS Setup ........................2-4 Entering BIOS Setup ..................2-4...
  • Page 7 Contents Chapter 3 I/O Information Front Panel Connectors ....................3-1 Front Panel........................3-2 VGA ........................ 3-3 COM1 and COM2................... 3-4 Ethernet ......................3-5 Parallel Port..................... 3-6 Universal Serial Bus..................3-8 PS/2 ......................... 3-9 Trigger......................3-10 Front Panel Features ...................... 3-10 Data Storage ........................
  • Page 8: About This Manual

    About This Manual This manual contains detailed instructions for installing and configuring your National Instruments NI PXI-8184/8185 embedded computer kit. How to Use the Documentation Set Begin by reading the NI PXI-8184/8185 Installation Guide, a brief quick-start guide that describes how to install and get started with your controller.
  • Page 9: Related Documentation

    About This Manual Text in this font denotes text or characters that you should enter from the monospace keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames, and extensions.
  • Page 10: Introduction

    NI PXI-8184/8185 controllers integrate standard I/O features in a single unit by using state-of-the-art packaging. Combining a NI PXI-8184/8185 embedded controller with a PXI-compatible chassis, such as the PXI-1042, results in a fully PC-compatible computer in a compact, rugged package. © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 11: Modules

    Chapter 1 Introduction Modules The standard I/O on both modules includes video, RS-232 serial port, parallel port, two USB ports, 10/100 ENET, PS/2 mouse and keyboard port, Reset button, and PXI Trigger. The modules have the following configurations: • The NI PXI-8185 has a 1.2 GHz processor, all the standard I/O, a second serial port, and a 30 GB (or larger) hard drive.
  • Page 12 Connectors Controller Triggers 10/100BaseT Ethernet Flash LPC Bus SMB to LPT 1 PXI Trigger PCI Bus Super I/O COM 1 Watchdog COM 2 PS/2 Keyboard/ Mouse Figure 1-1. NI PXI-8184/8185 Block Diagram © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 13: National Instruments Software

    • The 2.5 in. hard drive is 30 GB or larger. National Instruments Software National Instruments has developed several software kits you can use with the NI PXI-8184/8185. The software is already installed on your hard drive. NI-DAQ has an extensive library of functions that you can call from your application programming environment.
  • Page 14 NI-VISA You also can use the National Instruments LabVIEW and Measurement Studio application programs and instrument drivers to ease your programming task. These standardized programs match the modular virtual instrument capability of PXI and can reduce your PXI software development time.
  • Page 15: Installation And Configuration

    Touch the metal part of the case to discharge any static electricity that might be on your clothes or body. Remove the protective plastic covers from the four bracket-retaining screws as shown in Figure 2-1. © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 16 Chapter 2 Installation and Configuration 1 Protective Screw Cap (4X) Figure 2-1. Removing Protective Screw Caps Make sure the injector/ejector handle is in its downward position. Align the NI PXI-8184/8185 with the card guides on the top and bottom of the system controller slot. Caution Do not raise the injector/ejector handle as you insert the NI PXI-8184/8185.
  • Page 17 Chapter 5, Troubleshooting. Figure 2-2 shows an NI PXI-8185 installed in the system controller slot of a National Instruments PXI-1042 chassis. You can place PXI devices in any other slot. 1 PXI-1042 Chassis 2 NI PXI-8185 Controller 3 Injector/Ejector Rail Figure 2-2.
  • Page 18: How To Remove The Controller From The Pxi Chassis

    Chapter 2 Installation and Configuration How to Remove the Controller from the PXI Chassis The NI PXI-8184/8185 controllers are designed for easy handling. To remove the unit from the PXI chassis, complete the following steps: Power off the chassis. Remove the bracket-retaining screws in the front panel. Press the injector/ejector handle down.
  • Page 19: Main Setup Menu

    However, if an IDE/ATA device is not autodetected properly, you can specify it manually by pressing <Enter> on an item. • System Information—This setting displays a screen containing important system information about the NI PXI-8184/8185 controller. © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 20: Advanced Setup Menu

    Chapter 2 Installation and Configuration DMI Event Logging Submenu Major errors that occur during the BIOS booting process are stored in battery-backed memory on the controller, and remain there until you view and clear them using this submenu. This logging capability allows a system administrator to detect the historical occurrence of faults on a controller.
  • Page 21 Normally, using a Universal Serial Bus (USB) floppy drive is preferable to this option, which requires a specially designed drive and cable. (Refer to the Parallel © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 22: Pxi Setup Menu

    Chapter 2 Installation and Configuration Port section of Chapter 3, Information, for pinout information.) Setting this option to Parallel Port disables normal LPT1 functionality. The default is Disabled. • Legacy USB Support—Use this setting to use a USB keyboard and mouse as if they were standard PS/2-style peripherals.
  • Page 23: Security Setup Menu

    In most chassis configurations, an unauthorized user has easy access to the jumper that resets the CMOS contents to the factory default. For a secure setup of this controller, National Instruments recommends further provisions that are beyond the scope of this document.
  • Page 24: Boot Setup Menu

    Chapter 2 Installation and Configuration by 32-bit operating system drivers that access the hard disk directly. The default is No. Note To disable a current password, leave the new password field blank by pressing <Enter> on the field. Boot Setup Menu This screen displays the boot order of devices associated with the controller.
  • Page 25: System Cmos

    Figure 2-3. Wait one second. Move the jumper back to pins 1-2. Reinstall the controller in the chassis. Caution Do not leave the jumper on pins 2-3. Doing so decreases battery life. © National Instruments Corporation 2-11 NI PXI-8184/8185 User Manual...
  • Page 26: Labview Rt Configuration Switches

    Chapter 2 Installation and Configuration 1 Normal Operation (Default) 2 Clear CMOS Contents 3 Pin 1 Figure 2-3. Clearing the CMOS Contents (NI PXI-8185 Shown) Note For clarity, the battery is not shown in Figure 2-3. LabVIEW RT Configuration Switches Note These switches are functional only if the controller supports LabVIEW RT.
  • Page 27 Use this switch if moving the controller to a different subnet or if the current TCP/IP settings are invalid. Figure 2-4 shows the location of the LabVIEW RT configuration switches. The switches are shown in the OFF position. © National Instruments Corporation 2-13 NI PXI-8184/8185 User Manual...
  • Page 28: Drivers And Software

    National Instruments software manuals, all in Adobe Acrobat format. To access any manual, change your directory to NI PXI-8184/8185 User Manual 2-14...
  • Page 29: Pxi Features

    At the time of this manual’s publication, this software is not yet available; however, an interim trigger routing software utility is available from National Instruments. Contact National Instruments or refer to KnowledgeBase 2RCBPFWD at ni.com/support for more information.
  • Page 30 512 MB, 64 MB × 64, 7.5 ns, 1.05 in. max Note National Instruments has tested and verified that the SO-DIMMs we sell work with the NI PXI-8184/8185. We recommend you purchase your SO-DIMM modules from National Instruments. Other off-the-shelf SO-DIMM modules are not guaranteed to work properly.
  • Page 31: Hard Drive Recovery

    With DOS drivers, you can install Windows 9x operating systems. However, only a few USB CD-ROM drives have DOS drivers. As an alternative to a USB CD-ROM drive, you can use an external SCSI CD-ROM with a PXI-SCSI adapter. © National Instruments Corporation 2-17 NI PXI-8184/8185 User Manual...
  • Page 32: Installing From A Network

    Chapter 2 Installation and Configuration Installing from a Network Complete the following steps to install an OS from a network. Create a network bootdisk. (Refer to the file in the readme.txt folder on your OS installation CD.) netboot Use another PC on the network with a CD-ROM drive. Share the drive and load the OS installation CD.
  • Page 33: Front Panel Connectors

    Routing PXI triggers to or from the Both backplane trigger bus Note In this chapter, the NI PXI-8185 is shown in all illustrations. The connectors are in similar locations on the NI PXI-8184. © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 34: Front Panel

    Chapter 3 I/O Information Front Panel Figure 3-1 shows the front panel layout and dimensions of the NI PXI-8184/8185. Dimensions are in inches [millimeters]. 0.00 [0] 0.69 [17.5] 1.25 [31.8] 1.31 [33.3] 1.50 [38.1] 1.84 [46.7] 2.50 [63.5] 3.00 [76.2] 3.47 [88.1] Figure 3-1.
  • Page 35: Vga

    (housing) and 748333-2 (pin contact). 11 6 15 10 5 Figure 3-2. VGA Connector Location and Pinout Table 3-2. VGA Connector Signals Signal Name Signal Description Green Blue Not Connected Ground Ground Ground Ground © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 36: Com1 And Com2

    Chapter 3 I/O Information Table 3-2. VGA Connector Signals (Continued) Signal Name Signal Description Ground Not Connected Serial Data HSync Horizontal Sync VSync Vertical Sync Serial Clock COM1 and COM2 Figure 3-3 shows the location and pinouts for the COM1 and COM2 connectors on the NI PXI-8184/8185.
  • Page 37: Ethernet

    Figure 3-4 shows the location and pinouts for the Ethernet connector on the NI PXI-8184/8185. Table 3-4 lists and describes the Ethernet connector signals. AMP manufactures a mating connector, part number 554739-1. Ethernet Figure 3-4. Ethernet Connector Location and Pinout © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 38: Parallel Port

    Figure 3-5 shows the location and pinouts for the IEEE 1284 (parallel) connector on the NI PXI-8184/8185. Table 3-5 lists and describes the IEEE 1284 connector signals. Parallel port adapter cables are available from National Instruments, part number 777169-01. Parallel Port Figure 3-5.
  • Page 39 Write Gate AUTOFD Auto Line Feed DRVDEN0* Density Select +5 V +5 V 19–35 Ground Ground Not Connected Not Connected Refer to the BIOS Setup section of Chapter 2, Installation and Configuration. © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 40: Universal Serial Bus

    Chapter 3 I/O Information Universal Serial Bus Figure 3-6 shows the location and pinouts for the Universal Serial Bus (USB) connector on the NI PXI-8184/8185. Table 3-6 lists and describes the USB connector signals. AMP manufactures a USB mating connector, part number 787633. Figure 3-6.
  • Page 41 To connect both a PS/2 keyboard and PS/2 mouse to the NI PXI-8184/8185, use the Y-splitter adapter cable included with your controller (refer to Figure 4-1, Y-Splitter Cable). Replacement Y-splitter cables are available from National Instruments, part number 778713-01. PS/2 Figure 3-7. PS/2 Connector Location and Pinout Table 3-7. PS/2 Connector Signals...
  • Page 42: Trigger

    Chapter 3 I/O Information Trigger The TRG connector is the software-controlled trigger connection for routing PXI triggers to or from the backplane trigger bus. Figure 3-8 shows the TRG connector location on the NI PXI-8184/8185. Table 3-8 lists and describes the trigger connector signals. Figure 3-8.
  • Page 43: Data Storage

    The NI PXI-8184/8185 have the following data storage features: • Internal IDE hard drive – 2.5 in. notebook hard drive – Supports up to ATA-5 (UDMA 100) • USB storage support—USB CD-ROM, floppy drive, or mass storage device © National Instruments Corporation 3-11 NI PXI-8184/8185 User Manual...
  • Page 44: Common Configuration Questions

    Refer to the Entering BIOS Setup section of Chapter 2, Installation and Configuration, for more information. Can I use the internal IDE drive and an external SCSI hard drive at the same time? Yes. © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 45: Boot Options

    Chapter 4 Common Configuration Questions Boot Options What devices can I boot from? The NI PXI-8184/8185 can boot from the following devices: • The internal IDE hard drive • An external SCSI hard drive or CD-ROM if an SCSI adapter, such as the PXI-8214, is used •...
  • Page 46: Cables And Connections

    A connector. To use a device with a standard type A LPT connector, you need to use a type C-to-type A LPT adapter. Parallel port adapter cables, part number 777169-01, are available through the online catalog at ni.com/products © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 47: Operating System And Software Driver Installation

    Chapter 4 Common Configuration Questions Operating System and Software Driver Installation How do I install or reinstall the video driver? Refer to the file on the hard drive or recovery CD-ROM. Drivers.txt How do I install or reinstall the Ethernet driver? Refer to the file on the hard drive or recovery CD-ROM.
  • Page 48: Basic Pxi System Configuration

    Identify each chassis by right-clicking its entry, then selecting the appropriate chassis model through the Identify As submenu. Further expanding the PXI System branch shows all devices in the system that can be recognized by © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 49: Upgrade Information

    512 MB, 64 MB × 64, 7.5 ns, 1.05 in. max Note National Instruments has tested and verified that the SO-DIMMs we sell work with the NI PXI-8184/8185. We recommend you purchase your SO-DIMM modules from National Instruments. Other off-the-shelf SO-DIMM modules are not guaranteed to work properly.
  • Page 50 . To download the new BIOS, follow the instructions pxisupp.htm on the Web site. Where do I get the latest software drivers? You can download the latest drivers from ni.com/support/ pxisupp.htm © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 51: Pxi Configuration

    Boot Options section for more information. A USB floppy drive is available from National Instruments, part number 778492-02. The LPT port on the NI PXI-8184/8185 also can be configured through the BIOS setup for floppy signals instead of LPT signals. Refer to Chapter 3, Information, for the floppy drive pinout.
  • Page 52: Troubleshooting

    Does your monitor work with a different PC? If it hangs, note the last screen output that you saw for reference when consulting National Instruments technical support. • What has changed about the system? Did you recently move the...
  • Page 53 Chapter 5 Troubleshooting My controller boots fine until I get to Windows, at which point I cannot read the screen. This may include garbled output, white screen, black screen, or an out of sync message from the monitor. This problem usually results from having the video card output set past the limits of the monitor.
  • Page 54: Appendix A Specifications

    (3.2 × 5.1 × 8.5 in.) Slot requirements ........One system slot plus three controller expansion slots Compatibility ......... Fully compatible with PXI specification MTBF............. 180,000 h Weight ............ 1.02 Kg (2.26 lb) typical © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 55 Appendix A Specifications Operating Environment Ambient temperature range Chassis NI PXI-8185 PXI-1000B 5–50 °C PXI-1002 5–40 °C PXI-1006 5–50 °C PXI-1010 5–35 °C PXI-1011 5–50 °C PXI-1042 5–50 °C PXI-1045 5–55 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) Relative humidity range......10% to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.) Altitude ...........2,000 m (at 25 °C ambient...
  • Page 56 Note For UL and other safety certifications, refer to the product label or visit , search by model number or product line, and click the ni.com/certification appropriate link in the Certification column. © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 57 Appendix A Specifications Electromagnetic Compatibility Emissions..........EN 55011 Class A at 10 m FCC Part 15A above 1 GHz Immunity ..........EN 61326:1997 + A2:2001, Table 1 CE, C-Tick, and FCC Part 15 (Class A) Compliant Note For EMC compliance, operate this device with shielded cabling. CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows:...
  • Page 58 Relative humidity range ......10% to 90%, noncondensing (Tested in accordance with IEC-60068-2-56.) Altitude........... 2,000 m (at 25 °C ambient temperature) Pollution Degree ........2 For indoor or enclosed area use only. © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 59 Appendix A Specifications Caution Clean the PXI-8184 with a soft nonmetallic brush. Make sure that the device is completely dry and free from contaminants before returning it to service. Storage Environment Ambient temperature range ....–20 to 65 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) Relative humidity range......5% to 95% noncondensing...
  • Page 60 Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit , search by model number or product line, and click the ni.com/certification appropriate link in the Certification column. © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 61 Technical Support and Professional Services Visit the following sections of the National Instruments Web site at for technical support and professional services: ni.com Support—Online technical support resources at • ni.com/support include the following: – Self-Help Resources—For immediate answers and solutions,...
  • Page 62 Appendix B Technical Support and Professional Services If you searched and could not find the answers you need, contact ni.com your local office or NI corporate headquarters. Phone numbers for our worldwide offices are listed at the front of this manual. You also can visit the Worldwide Offices section of to access the branch ni.com/niglobal...
  • Page 63 Symbols ° Degrees Ω Ohms Percent Amperes Alternating Current ASIC Application-specific integrated circuit Bytes backplane An assembly, typically a printed circuit board, with connectors and signal paths that bus the connector pins © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 64 Glossary BIOS Basic Input/Output System. BIOS functions are the fundamental level of any PC or compatible computer. BIOS functions embody the basic operations needed for successful use of the computer’s hardware resources. Celsius cache Small portion of high-speed memory used for temporary storage of frequently used data CMOS Complementary Metal Oxide Semiconductor;...
  • Page 65 Hertz; cycles per second Input/output; the techniques, media, and devices used to achieve communication between machines and users Integrated Drive Electronics; hard disk and built-in controller IEEE Institute of Electrical and Electronics Engineers Inches © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 66 Glossary instrument driver A set of routines designed to control a specific instrument or family of instruments, and any necessary related files for LabWindows/CVI or LabVIEW interrupt A means for a device to request service from another device interrupt level The relative priority at which a device can interrupt IRQ* Interrupt signal...
  • Page 67 NI-DAQ The National Instruments software for data acquisition instruments NI-VISA The National Instruments implementation of the VISA standard; an interface-independent software that provides a unified programming interface for VXI, GPIB, and serial instruments Non-maskable interrupt; high-priority interrupt that cannot be disabled by another interrupt.
  • Page 68 Glossary resource Hardware settings used by devices in a computer system, including ISA interrupt level, DMA channel, and I/O address Root mean squared. See also Real Time Clock; an electronic circuit that maintains the time of day, and also can provide timing signals for timesharing operations Seconds slave A functional part of a PXI device that detects data transfer cycles initiated...
  • Page 69 (table), 3-5 documentation common configuration questions how to use this documentation set, vii boot options, 4-2 NI resources, B-1 cables and connections, 4-3 DRIVE LED, 3-10 chassis configuration, 4-4 driver installation, 4-4 © National Instruments Corporation NI PXI-8184/8185 User Manual...
  • Page 70 Index drivers, 2-14 installation installation, video, 4-4 See also configuration obtaining latest drivers, 4-7 configuration in MAX (figure), 4-5 drivers (NI resources), B-1 injector/ejector handle position (caution), 2-2 NI PXI-8185 installed in a PXI chassis (figure), 2-3 Ethernet, connector procedure, 2-1 location and pinout (figure), 3-5 removing NI PXI-8184/8185 from PXI chassis, 2-4...
  • Page 71 2-17 into controller, 4-3 installing in a PXI chassis, 2-1 (figure), 2-3 installing SO-DIMMs (figure), 2-16, 4-7 logic blocks, 1-4 National Instruments software, 1-4 modules, 1-2 National Instruments support and National Instruments software, 1-4 services, B-1 peripheral expansion overview...
  • Page 72 2-14 designs, 1-1 installing from CD-ROM, 4-4 peripheral expansion overview (table), 3-1 LabVIEW, 1-5 POWER OK LED, 3-10 National Instruments software, 1-4 programming examples (NI resources), B-1 NI-DAQ, 1-4 protective screw caps, removing (figure), 2-2 NI-VISA, 1-5 PS/2...
  • Page 73 (figure), 3-8 connector signals (table), 3-8 overview (table), 3-1 connector signals (table), 3-3 location and pinout (figure), 3-3 overview (table), 3-1 video, 3-1 See also VGA driver installation, 4-4 © National Instruments Corporation NI PXI-8184/8185 User Manual...

This manual is also suitable for:

Ni pxi-8185Ni pxi-8184

Table of Contents