Figure 3-2. Output Levels And Load Termination Using A 50; Arb Connector - National Instruments DAQArb 5411 User Manual

High-speed arbitrary waveform generator
Hide thumbs Also See for DAQArb 5411:
Table of Contents

Advertisement

Chapter 3
Signal Connections

ARB Connector

Note:
DAQArb 5411 User Manual
The ARB connector provides the waveform output. The maximum
output levels on this connector depend on the type of load termination.
If the output of a DAQArb 5411 terminates into a 50
levels are ±5 V, as shown in Figure 3-2. If the output of DAQArb 5411
terminates into a high impedance load (HiZ), the output levels are
±10 V. If the output terminates into any other load, the levels are:
where V
is the maximum output voltage level, R
out
impedance in ohms, and R
DAQArb 5411. By default, R
to 75
.
Software will set the voltage output levels based on a 50
For more information on waveform generation and analog output
operation, refer to Chapter 4, Arb Operation. For specifications on the
waveform output signal, see Appendix A, Specifications.

Figure 3-2. Output Levels and Load Termination Using a 50

R
L
=
x 10 V
V
out
R
+ R
L
O
is the output impedance on the
O
= 50
, but the software can also set it
O
DAQArb 5411
Load
ARB
R
=
R
=
O
L
50
50
50
Load
DAQArb 5411
ARB
Load
R
=
R
=
O
L
50
HiZ
High Impedance Load
3-2
load, the output
is the load
L
load termination.
5 V
10 V
Output Impedance
© National Instruments Corporation