1. SPECIFICATIONS ..................................................................................................................................................H2i-R2-4
1-1. PURY-HP72~192T(S)KMU-A-H Specifications .............................................................................................H2i-R2-4
1-2. PURY-HP72~192Y(S)KMU-A Specifications ................................................................................................H2i-R2-7
2. EXTERNAL DIMENSIONS ...................................................................................................................................H2i-R2-11
3. CENTER OF GRAVITY ........................................................................................................................................H2i-R2-17
4. ELECTRICAL WIRING DIAGRAMS .....................................................................................................................H2i-R2-18
5. REFRIGERANT CIRCUIT DIAGRAMS ................................................................................................................H2i-R2-20
6. SOUND PRESSURE LEVELS .............................................................................................................................H2i-R2-22
7. CAPACITY TABLES .............................................................................................................................................H2i-R2-24
7-1. Correction by Temperature (Standard Performance) in Fahrenheit ............................................................H2i-R2-24
7-1-1. Cooling Capacity/Power Input with PURY-HP72TKMU-A-H ..........................................................H2i-R2-24
7-1-2. Cooling Capacity/Power Input with PURY-HP96TKMU-A-H ..........................................................H2i-R2-25
7-1-3. Cooling Capacity/Power Input with PURY-HP144TSKMU-A-H .....................................................H2i-R2-26
7-1-4. Cooling Capacity/Power Input with PURY-HP192TSKMU-A-H .....................................................H2i-R2-27
7-1-5. Heating Capacity/Power Input with PURY-HP72TKMU-A-H .........................................................H2i-R2-28
7-1-6. Heating Capacity/Power Input with PURY-HP96TKMU-A-H .........................................................H2i-R2-29
7-1-7. Heating Capacity/Power Input with PURY-HP144TSKMU-A-H .....................................................H2i-R2-30
7-1-8. Heating Capacity/Power Input with PURY-HP192TSKMU-A-H .....................................................H2i-R2-31
7-2. Correction by Temperature (High Heating Performance) in Fahrenheit ......................................................H2i-R2-32
7-2-1. Heating Capacity/Power Input (High Heat Performance) with PURY-HP72TKMU-A-H ...............H2i-R2-32
7-2-2. Heating Capacity/Power Input (High Heat Performance) with PURY-HP96TKMU-A-H ................H2i-R2-33
7-2-3. Heating Capacity/Power Input (High Heat Performance) with PURY-HP144TSKMU-A-H ............H2i-R2-34
7-2-4. Heating Capacity/Power Input (High Heat Performance) with PURY-HP192TSKMU-A-H ...........H2i-R2-35
7-3. Correction by Temperature (Intelligent Heat Performance) in Fahrenheit ...................................................H2i-R2-36
7-3-1. Heating Capacity/Power Input (Intelligent Heat Performance) with PURY-HP72TKMU-A-H ........H2i-R2-36
7-3-2. Heating Capacity/Power Input (Intelligent Heat Performance) with PURY-HP96TKMU-A-H ........H2i-R2-37
7-3-3. Heating Capacity/Power Input (Intelligent Heat Performance) with PURY-HP144TSKMU-A-H ....H2i-R2-38
7-3-4. Heating Capacity/Power Input (Intelligent Heat Performance) with PURY-HP192TSKMU-A-H ....H2i-R2-39
7-4. Correction by Temperature/Total Indoor in Fahrenheit ................................................................................H2i-R2-40
7-4-1. Cooling Capacity with PURY-HP72TKMU-A-H .............................................................................H2i-R2-40
7-4-2. Cooling Capacity with PURY-HP96TKMU-A-H ..............................................................................H2i-R2-44
7-4-3. Cooling Capacity with PURY-HP144TSKMU-A-H .........................................................................H2i-R2-48
7-4-4. Cooling Capacity with PURY-HP192TSKMU-A-H .........................................................................H2i-R2-52
7-4-5. Cooling Capacity with PURY-HP72YKMU-A ..................................................................................H2i-R2-56
7-4-6. Cooling Capacity with PURY-HP96YKMU-A ..................................................................................H2i-R2-60
7-4-7. Cooling Capacity with PURY-HP144YSKMU-A .............................................................................H2i-R2-64
7-4-8. Cooling Capacity with PURY-HP192YSKMU-A .............................................................................H2i-R2-68
7-4-9. Heating Capacity with PURY-HP72TKMU-A-H ..............................................................................H2i-R2-72
7-4-10. Heating Capacity with PURY-HP96TKMU-A-H ............................................................................H2i-R2-75
7-4-11. Heating Capacity with PURY-HP144TSKMU-A-H .......................................................................H2i-R2-78
7-4-12. Heating Capacity with PURY-HP192TSKMU-A-H .......................................................................H2i-R2-81
7-4-13. Heating Capacity with PURY-HP72YKMU-A ...............................................................................H2i-R2-84
7-4-14. Heating Capacity with PURY-HP96YKMU-A ..............................................................................H2i-R2-87
7-4-15. Heating Capacity with PURY-HP144YSKMU-A ...........................................................................H2i-R2-90
7-4-16. Heating Capacity with PURY-HP192YSKMU-A ...........................................................................H2i-R2-93
7-4-17. Heating Capacity [High Heat Performance Mode] with PURY-HP72TKMU-A-H .........................H2i-R2-96
7-4-18. Heating Capacity [High Heat Performance Mode] with PURY-HP96TKMU-A-H .........................H2i-R2-99
© 2014 Mitsubishi Electric US, Inc.
PURY-HP-T(S)KMU,-Y(S)KMU (September 2014)
H2i-R2-1

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi H2i-R2-1

  • Page 1 7-4-15. Heating Capacity with PURY-HP144YSKMU-A ................H2i-R2-90 7-4-16. Heating Capacity with PURY-HP192YSKMU-A ................H2i-R2-93 7-4-17. Heating Capacity [High Heat Performance Mode] with PURY-HP72TKMU-A-H ......H2i-R2-96 7-4-18. Heating Capacity [High Heat Performance Mode] with PURY-HP96TKMU-A-H ......H2i-R2-99 H2i-R2-1 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 2 7-8-29. Heating Capacity [Intelligent Heat Mode] with PURY-HP72YKMU-A ........H2i-R2-240 7-8-30. Heating Capacity [Intelligent Heat Mode] with PURY-HP96YKMU-A ........H2i-R2-243 7-8-31. Heating Capacity [Intelligent Heat Mode] with PURY-HP144YSKMU-A ........H2i-R2-246 7-8-32. Heating Capacity [Intelligent Heat Mode] with PURY-HP192YSKMU-A ........H2i-R2-249 H2i-R2-2 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 3 7-12. Extended Cooling Range with Low Ambient Kit ..................H2i-R2-256 8. OPTIONAL PARTS .............................H2i-R2-257 8-1. Branch Joints ............................H2i-R2-257 8-2. Twinning Kit ...............................H2i-R2-258 8-3. Joint Adapter Kit ............................H2i-R2-259 8-4. Low Ambient Kit ............................H2i-R2-260 8-5. Snow/Hail Guards Kit ..........................H2i-R2-263 H2i-R2-3 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 4: Specifications

    Installation Manual. *3 Harsh weather environments may demand performance enhancing equipment. Ask your Mitsubishi Electric representative for more details on your region. *4 For details on the electrical data needed for installing these units, Remark see the H2i R2-Series System Design section.
  • Page 5 Installation Manual. *3 Harsh weather environments may demand performance enhancing equipment. Ask your Mitsubishi Electric representative for more details on your region. *4 For details on the electrical data needed for installing these units, Remark see the H2i R2-Series System Design section.
  • Page 6 Installation Manual. *3 Harsh weather environments may demand performance enhancing equipment. Ask your Mitsubishi Electric representative for more details on your region. *4 For details on the electrical data needed for installing these units, Remark see the H2i R2-Series System Design section.
  • Page 7 Installation Manual. *3 Harsh weather environments may demand performance enhancing equipment. Ask your Mitsubishi Electric representative for more details on your region. *4 For details on the electrical data needed for installing these units, Remark see the H2i R2-Series System Design section.
  • Page 8 Installation Manual. *3 Harsh weather environments may demand performance enhancing equipment. Ask your Mitsubishi Electric representative for more details on your region. *4 For details on the electrical data needed for installing these units, Remark see the H2i R2-Series System Design section.
  • Page 9 Installation Manual. *3 Harsh weather environments may demand performance enhancing equipment. Ask your Mitsubishi Electric representative for more details on your region. *4 For details on the electrical data needed for installing these units, Remark see the H2i R2-Series System Design section.
  • Page 10 22.1 / 22.0 PURY-HP192YSKMU-A Ducted / Non-Ducted 11.1 / 12.1 16.1 / 16.6 3.32 / 3.31 2.24 / 2.05 16.9 / 21.4 *1. Efficiency values based on AHRI 1230 test method. Note: H2i-R2-10 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 11 2. EXTERNAL DIMENSIONS 2. EXTERNAL DIMENSIONS DATA U10 2. EXTERNAL DIMENSIONS PURY-HP72, 96TKMU-A-H(-BS) Unit : mm(in) H2i-R2-11 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 252 © 2014 Mitsubishi Electric US, Inc.
  • Page 12: External Dimensions

    2. EXTERNAL DIMENSIONS 2. EXTERNAL DIMENSIONS DATA U10 PURY-HP72, 96TKMU-A-H(-BS) Unit : mm(in) H2i-R2-12 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 253 © 2014 Mitsubishi Electric US, Inc.
  • Page 13 2. EXTERNAL DIMENSIONS 2. EXTERNAL DIMENSIONS DATA U10 PURY-HP144, 192TSKMU-A-H(-BS) Unit : mm(in) H2i-R2-13 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 254 © 2014 Mitsubishi Electric US, Inc.
  • Page 14 2. EXTERNAL DIMENSIONS 2. EXTERNAL DIMENSIONS DATA U10 PURY-HP72, 96YKMU-A(-BS) Unit : mm(in) H2i-R2-14 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 255 © 2014 Mitsubishi Electric US, Inc.
  • Page 15 2. EXTERNAL DIMENSIONS 2. EXTERNAL DIMENSIONS DATA U10 PURY-HP72, 96YKMU-A(-BS) Unit : mm(in) H2i-R2-15 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 256 © 2014 Mitsubishi Electric US, Inc.
  • Page 16 2. EXTERNAL DIMENSIONS 2. EXTERNAL DIMENSIONS DATA U10 PURY-HP144, 192YSKMU-A(-BS) Unit : mm(in) H2i-R2-16 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 257 © 2014 Mitsubishi Electric US, Inc.
  • Page 17 PURY-HP72, 96YKMU-A (-BS) 1220 Unit : mm[in.] Model PURY-HP72TKMU-A-H 460[18-1/8] 320[12-5/8] 609[23] PURY-HP96TKMU-A-H 447[17-5/8] 311[12-1/4] 595[23-7/16] 447[17-5/8] 310[12-7/32] 623[24-17/32] PURY-HP72YKMU-A PURY-HP96YKMU-A 435[17-5/32] 302[11-29/32] 610[24-1/32] 1060 OUTDOOR UNITS 2 - 258 H2i-R2-17 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 18 4. ELECTRICAL WIRING DIAGRAMS 4. ELECTRICAL WIRING DIAGRAMS DATA U10 4. ELECTRICAL WIRING DIAGRAMS PURY-HP72, 96TKMU-A-H(-BS) H2i-R2-18 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 259 © 2014 Mitsubishi Electric US, Inc.
  • Page 19: Electrical Wiring Diagrams

    4. ELECTRICAL WIRING DIAGRAMS 4. ELECTRICAL WIRING DIAGRAMS DATA U10 PURY-HP72, 96YKMU-A(-BS) H2i-R2-19 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 260 © 2014 Mitsubishi Electric US, Inc.
  • Page 20: Refrigerant Circuit Diagrams

    Solenoid valve block SV11 SV4d SV4a SV4b ST17 63H1 63HS1 CV7a SV10 LEV5a 63LS SV1a TH11 CV3a CV2a CV5a ST18 CV8a CV9a SV5b COMP CV6a CV4a LEV4 - 67 - HWE13080 H2i-R2-20 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 21 ST17 side junction pipe 63H1 63HS1 CV7a SV10 LEV5a 63LS SV1a TH11 CV3a CV2a CV5a Low-pressure ST18 side distributor CV8a CV9a SV5b COMP CV6a CV4a LEV4 - 68 - HWE13080 H2i-R2-21 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 22 Low noise mode automatically in the case that the operation condition is severe. from Low noise mode automatically in the case that the operation condition is severe. H2i-R2-22 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 261 © 2014 Mitsubishi Electric US, Inc.
  • Page 23 Low noise mode automatically in the case that the operation condition is severe. from Low noise mode automatically in the case that the operation condition is severe. H2i-R2-23 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 262 © 2014 Mitsubishi Electric US, Inc.
  • Page 24 67FWB 64FWB 61FWB 61FWB 59FWB Outdoor Temperature (FDB) 75FWB 72FWB 69FWB 67FWB 64FWB 61FWB 61FWB 59FWB 23.0 32.0 41.0 50.0 59.0 68.0 77.0 86.0 95.0 104.0 113.0 Outdoor Temperature (FDB) H2i-R2-24 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 25 64FWB 61FWB 61FWB 59FWB Outdoor Temperature (FDB) 75FWB 72FWB 72FWB 69FWB 67FWB 64FWB 61FWB 61FWB 59FWB 23.0 32.0 41.0 50.0 59.0 68.0 77.0 86.0 95.0 104.0 113.0 Outdoor Temperature (FDB) H2i-R2-25 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 26 64FWB 61FWB 61FWB 59FWB Outdoor Temperature (FDB) 75FWB 72FWB 72FWB 69FWB 67FWB 64FWB 61FWB 61FWB 59FWB 23.0 32.0 41.0 50.0 59.0 68.0 77.0 86.0 95.0 104.0 113.0 Outdoor Temperature (FDB) H2i-R2-26 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 27 64FWB 61FWB 61FWB 59FWB Outdoor Temperature (FDB) 75FWB 72FWB 72FWB 69FWB 67FWB 64FWB 61FWB 61FWB 59FWB 23.0 32.0 41.0 50.0 59.0 68.0 77.0 86.0 95.0 104.0 113.0 Outdoor Temperature (FDB) H2i-R2-27 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 28: Capacity Tables

    -10.0 10.0 20.0 30.0 40.0 50.0 60.0 Outdoor Temperature (FWB) H2i-R2-28 H2i-R2-28 H2i-R2-28 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc.
  • Page 29 -10.0 10.0 20.0 30.0 40.0 50.0 60.0 Outdoor Temperature (FWB) H2i-R2-29 H2i-R2-28 H2i-R2-28 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc.
  • Page 30 -10.0 10.0 20.0 30.0 40.0 50.0 60.0 Outdoor Temperature (FWB) H2i-R2-30 H2i-R2-28 H2i-R2-28 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc.
  • Page 31 -10.0 10.0 20.0 30.0 40.0 50.0 60.0 Outdoor Temperature (FWB) H2i-R2-31 H2i-R2-28 H2i-R2-28 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc.
  • Page 32 Outdoor Temperature (FWB) Outdoor Temperature (FWB) Outdoor Temperature (FWB) 59FDB 59FDB 59FDB 70FWB 70FDB 70FDB 77FWB 77FDB 77FDB 81FWB 81FDB 81FDB -20.0 -10.0 10.0 20.0 30.0 40.0 50.0 60.0 Outdoor Temperature (FWB) H2i-R2-32 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 33 -10.0 10.0 20.0 30.0 40.0 50.0 60.0 Outdoor Temperature (FWB) H2i-R2-33 H2i-R2-28 H2i-R2-28 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc.
  • Page 34 -10.0 10.0 20.0 30.0 40.0 50.0 60.0 Outdoor Temperature (FWB) H2i-R2-34 H2i-R2-28 H2i-R2-28 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc.
  • Page 35 -10.0 10.0 20.0 30.0 40.0 50.0 60.0 Outdoor Temperature (FWB) H2i-R2-35 H2i-R2-28 H2i-R2-28 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc.
  • Page 36 Outdoor Temperature (FWB) Outdoor Temperature (FWB) Outdoor Temperature (FWB) 59FDB 59FDB 59FDB 70FWB 70FDB 70FDB 77FWB 77FDB 77FDB 81FWB 81FDB 81FDB -20.0 -10.0 10.0 20.0 30.0 40.0 50.0 60.0 Outdoor Temperature (FWB) H2i-R2-36 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 37 -10.0 10.0 20.0 30.0 40.0 50.0 60.0 Outdoor Temperature (FWB) H2i-R2-37 H2i-R2-28 H2i-R2-28 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc.
  • Page 38 -10.0 10.0 20.0 30.0 40.0 50.0 60.0 Outdoor Temperature (FWB) H2i-R2-38 H2i-R2-28 H2i-R2-28 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc.
  • Page 39 -10.0 10.0 20.0 30.0 40.0 50.0 60.0 Outdoor Temperature (FWB) H2i-R2-39 H2i-R2-28 H2i-R2-28 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc. © 2014 Mitsubishi Electric US, Inc.
  • Page 40 72400 20500 75700 20800 80200 21200 115.0 49800 12800 51700 14000 55500 15400 58400 15500 59400 16400 62700 16800 67200 17100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-40 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 41 20800 115.0 46900 12600 48700 13700 52300 15100 55000 15200 55900 16200 59000 16500 63200 16900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-41 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 268...
  • Page 42 14300 115.0 32800 8700 34100 9500 36600 10400 38500 10500 39100 11100 41300 11400 44300 11600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-42 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 269...
  • Page 43 10700 115.0 23400 6500 24300 7000 26100 7800 27500 7800 27900 8300 29500 8500 31600 8600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-43 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 270...
  • Page 44 31600 115.0 66500 19200 69000 20900 74100 23000 78000 23100 79200 24600 83700 25100 89700 25600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-44 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 275...
  • Page 45 31400 115.0 62400 19000 64800 20700 69600 22800 73200 23000 74400 24400 78600 24900 84200 25400 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-45 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 276...
  • Page 46 20200 115.0 43700 12200 45400 13300 48700 14700 51300 14700 52100 15700 55000 16000 59000 16300 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-46 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 277...
  • Page 47 14400 115.0 31200 8800 32400 9500 34800 10500 36600 10600 37200 11200 39300 11500 42100 11700 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-47 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 278...
  • Page 48 45300 115.0 99600 27400 103400 29900 111100 32900 116800 33100 118700 35100 125400 35900 134400 36700 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-48 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 283...
  • Page 49 44500 115.0 93700 27000 97300 29400 104500 32400 109900 32500 111700 34600 118000 35300 126500 36100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-49 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 284...
  • Page 50 30700 115.0 65600 18600 68100 20200 73100 22300 76900 22400 78200 23800 82600 24300 88500 24800 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-50 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 285...
  • Page 51 22800 115.0 46900 13800 48700 15100 52300 16600 55000 16700 55900 17700 59000 18100 63300 18500 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-51 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 286...
  • Page 52 65600 115.0 133100 39800 138300 43300 148500 47700 156200 47900 158700 50900 167600 52000 179700 53100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-52 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 291...
  • Page 53 65100 115.0 125000 39500 129800 43000 139400 47300 146600 47600 149000 50600 157400 51600 168700 52700 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-53 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 292...
  • Page 54 41800 115.0 87500 25300 90900 27600 97600 30400 102700 30600 104300 32500 110200 33200 118200 33900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-54 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 293...
  • Page 55 29900 115.0 62500 18100 64900 19800 69700 21800 73300 21900 74500 23200 78700 23700 84400 24200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-55 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 294...
  • Page 56 21200 115.0 49800 12800 51700 14000 55500 15400 58400 15500 59400 16400 62700 16800 67200 17100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-56 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 299...
  • Page 57 20800 115.0 46900 12600 48700 13700 52300 15100 55000 15200 55900 16200 59000 16500 63200 16900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-57 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 300...
  • Page 58 14300 115.0 32800 8700 34100 9500 36600 10400 38500 10500 39100 11100 41300 11400 44300 11600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-58 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 301...
  • Page 59 10700 115.0 23400 6500 24300 7000 26100 7800 27500 7800 27900 8300 29500 8500 31600 8600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-59 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 302...
  • Page 60 31600 115.0 66500 19200 69000 20900 74100 23000 78000 23100 79200 24600 83700 25100 89700 25600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-60 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 307...
  • Page 61 31400 115.0 62400 19000 64800 20700 69600 22800 73200 23000 74400 24400 78600 24900 84200 25400 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-61 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 308...
  • Page 62 20200 115.0 43700 12200 45400 13300 48700 14700 51300 14700 52100 15700 55000 16000 59000 16300 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-62 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 309...
  • Page 63 14400 115.0 31200 8800 32400 9500 34800 10500 36600 10600 37200 11200 39300 11500 42100 11700 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-63 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 310...
  • Page 64 45300 115.0 99600 27400 103400 29900 111100 32900 116800 33100 118700 35100 125400 35900 134400 36700 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-64 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 315...
  • Page 65 44500 115.0 93700 27000 97300 29400 104500 32400 109900 32500 111700 34600 118000 35300 126500 36100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-65 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 316...
  • Page 66 30700 115.0 65600 18600 68100 20200 73100 22300 76900 22400 78200 23800 82600 24300 88500 24800 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-66 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 317...
  • Page 67 22800 115.0 46900 13800 48700 15100 52300 16600 55000 16700 55900 17700 59000 18100 63300 18500 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-67 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 318...
  • Page 68 65600 115.0 133100 39800 138300 43300 148500 47700 156200 47900 158700 50900 167600 52000 179700 53100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-68 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 323...
  • Page 69 65100 115.0 125000 39500 129800 43000 139400 47300 146600 47600 149000 50600 157400 51600 168700 52700 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-69 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 324...
  • Page 70 41800 115.0 87500 25300 90900 27600 97600 30400 102700 30600 104300 32500 110200 33200 118200 33900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-70 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 325...
  • Page 71 29900 115.0 62500 18100 64900 19800 69700 21800 73300 21900 74500 23200 78700 23700 84400 24200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-71 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 326...
  • Page 72 21400 80200 17300 67300 14200 57700 11800 59.0 99400 21500 80200 16800 67300 13400 57700 11200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-72 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 330...
  • Page 73 17400 63800 14100 53600 11600 46000 9600 59.0 79200 17500 63800 13700 53600 10900 46000 9100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-73 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 331...
  • Page 74 11200 39900 9100 33500 7400 28700 6200 59.0 49500 11200 39900 8800 33500 7000 28700 5800 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-74 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 332...
  • Page 75 30700 108300 24900 91000 20300 78000 17000 59.0 134300 30800 108300 24100 91000 19300 78000 16000 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-75 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 336...
  • Page 76 16900 62300 14100 55.0 102700 23800 86600 19300 72700 15700 62300 13100 59.0 107400 23900 86600 18600 72700 14900 62300 12400 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-76 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 77 14300 54100 11600 45400 9500 39000 7900 59.0 67100 14300 54100 11200 45400 9000 39000 7500 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-77 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 338...
  • Page 78 44800 160800 36300 135000 29700 115700 24800 59.0 199300 45000 160800 35200 135000 28100 115700 23400 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-78 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 342...
  • Page 79 26100 92200 21800 55.0 151800 36600 128000 29700 107500 24200 92200 20200 59.0 158700 36700 128000 28700 107500 23000 92200 19100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-79 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 80 16700 57600 13900 55.0 94900 23400 80000 19000 67200 15500 57600 12900 59.0 99200 23500 80000 18400 67200 14700 57600 12200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-80 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 81 64000 215300 51900 180800 42400 155000 35400 59.0 266900 64300 215300 50300 180800 40200 155000 33500 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-81 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 348...
  • Page 82 49500 172000 40200 144500 32800 123900 27400 59.0 213300 49800 172000 38900 144500 31100 123900 25900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-82 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 349...
  • Page 83 21200 77400 17700 55.0 127500 29800 107500 24200 90300 19700 77400 16500 59.0 133300 29900 107500 23400 90300 18700 77400 15600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-83 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 84 21400 80200 17300 67300 14200 57700 11800 59.0 99400 21500 80200 16800 67300 13400 57700 11200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-84 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 354...
  • Page 85 17400 63800 14100 53600 11600 46000 9600 59.0 79200 17500 63800 13700 53600 10900 46000 9100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-85 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 355...
  • Page 86 8000 28700 6600 55.0 47300 11200 39900 9100 33500 7400 28700 6200 59.0 49500 11200 39900 8800 33500 7000 28700 5800 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-86 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 87 30700 108300 24900 91000 20300 78000 17000 59.0 134300 30800 108300 24100 91000 19300 78000 16000 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-87 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 360...
  • Page 88 23800 86600 19300 72700 15700 62300 13100 59.0 107400 23900 86600 18600 72700 14900 62300 12400 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-88 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 361...
  • Page 89 10200 39000 8500 55.0 64200 14300 54100 11600 45400 9500 39000 7900 59.0 67100 14300 54100 11200 45400 9000 39000 7500 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-89 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 90 44800 160800 36300 135000 29700 115700 24800 59.0 199300 45000 160800 35200 135000 28100 115700 23400 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-90 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 366...
  • Page 91 26100 92200 21800 55.0 151800 36600 128000 29700 107500 24200 92200 20200 59.0 158700 36700 128000 28700 107500 23000 92200 19100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-91 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 92 23400 80000 19000 67200 15500 57600 12900 59.0 99200 23500 80000 18400 67200 14700 57600 12200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-92 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 368...
  • Page 93 64000 215300 51900 180800 42400 155000 35400 59.0 266900 64300 215300 50300 180800 40200 155000 33500 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-93 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 372...
  • Page 94 49500 172000 40200 144500 32800 123900 27400 59.0 213300 49800 172000 38900 144500 31100 123900 25900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-94 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 373...
  • Page 95 29800 107500 24200 90300 19700 77400 16500 59.0 133300 29900 107500 23400 90300 18700 77400 15600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-95 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 374...
  • Page 96 21400 80200 17300 67300 14400 57700 12000 59.0 99400 21500 80200 16800 67300 14100 57700 11700 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-96 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 378...
  • Page 97 12200 46000 10300 55.0 75700 17400 63800 14100 53600 11700 46000 9800 59.0 79200 17500 63800 13700 53600 11500 46000 9600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-97 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 98 7800 28700 6600 55.0 47300 11200 39900 9100 33500 7500 28700 6300 59.0 49500 11200 39900 8800 33500 7400 28700 6100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-98 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 99 30700 108300 24900 91000 20600 78000 17300 59.0 134300 30800 108300 24100 91000 20200 78000 16900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-99 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 384...
  • Page 100 16700 62300 14000 55.0 102700 23800 86600 19300 72700 16000 62300 13400 59.0 107400 23900 86600 18600 72700 15600 62300 13100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-100 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 101 10000 39000 8400 55.0 64200 14300 54100 11600 45400 9600 39000 8100 59.0 67100 14300 54100 11200 45400 9400 39000 7900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-101 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 102 44800 160800 36300 135000 30100 115700 25300 59.0 199300 45000 160800 35200 135000 29500 115700 24700 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-102 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 390...
  • Page 103 25700 92200 21600 55.0 151800 36600 128000 29700 107500 24600 92200 20600 59.0 158700 36700 128000 28700 107500 24100 92200 20100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-103 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 104 16400 57600 13800 55.0 94900 23400 80000 19000 67200 15700 57600 13200 59.0 99200 23500 80000 18400 67200 15400 57600 12900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-104 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 105 64000 215300 51900 180800 43000 155000 36100 59.0 266900 64300 215300 50300 180800 42200 155000 35200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-105 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 396...
  • Page 106 34800 123900 29200 55.0 204000 49500 172000 40200 144500 33300 123900 27900 59.0 213300 49800 172000 38900 144500 32600 123900 27200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-106 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 107 20900 77400 17600 55.0 127500 29800 107500 24200 90300 20000 77400 16800 59.0 133300 29900 107500 23400 90300 19600 77400 16400 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-107 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 108 21400 80200 17300 67300 14400 57700 12000 59.0 99400 21500 80200 16800 67300 14100 57700 11700 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-108 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 402...
  • Page 109 12200 46000 10300 55.0 75700 17400 63800 14100 53600 11700 46000 9800 59.0 79200 17500 63800 13700 53600 11500 46000 9600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-109 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 110 7800 28700 6600 55.0 47300 11200 39900 9100 33500 7500 28700 6300 59.0 49500 11200 39900 8800 33500 7400 28700 6100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-110 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 111 30700 108300 24900 91000 20600 78000 17300 59.0 134300 30800 108300 24100 91000 20200 78000 16900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-111 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 408...
  • Page 112 16700 62300 14000 55.0 102700 23800 86600 19300 72700 16000 62300 13400 59.0 107400 23900 86600 18600 72700 15600 62300 13100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-112 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 113 10000 39000 8400 55.0 64200 14300 54100 11600 45400 9600 39000 8100 59.0 67100 14300 54100 11200 45400 9400 39000 7900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-113 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 114 44800 160800 36300 135000 30100 115700 25300 59.0 199300 45000 160800 35200 135000 29500 115700 24700 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-114 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 414...
  • Page 115 25700 92200 21600 55.0 151800 36600 128000 29700 107500 24600 92200 20600 59.0 158700 36700 128000 28700 107500 24100 92200 20100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-115 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 116 16400 57600 13800 55.0 94900 23400 80000 19000 67200 15700 57600 13200 59.0 99200 23500 80000 18400 67200 15400 57600 12900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-116 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 117 64000 215300 51900 180800 43000 155000 36100 59.0 266900 64300 215300 50300 180800 42200 155000 35200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-117 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 420...
  • Page 118 34800 123900 29200 55.0 204000 49500 172000 40200 144500 33300 123900 27900 59.0 213300 49800 172000 38900 144500 32600 123900 27200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-118 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 119 29800 107500 24200 90300 20000 77400 16800 59.0 133300 29900 107500 23400 90300 19600 77400 16400 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-119 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 422...
  • Page 120 21400 80200 17300 67300 14200 57700 11800 59.0 99400 21500 80200 16800 67300 13500 57700 11200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-120 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 426...
  • Page 121 12400 46000 10400 55.0 75700 17400 63800 14100 53600 11600 46000 9600 59.0 79200 17500 63800 13700 53600 11000 46000 9100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-121 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 122 7900 28700 6600 55.0 47300 11200 39900 9100 33500 7400 28700 6200 59.0 49500 11200 39900 8800 33500 7100 28700 5900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-122 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 123 30700 108300 24900 91000 20400 78000 17000 59.0 134300 30800 108300 24100 91000 19400 78000 16100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-123 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 432...
  • Page 124 16900 62300 14100 55.0 102700 23800 86600 19300 72700 15800 62300 13100 59.0 107400 23900 86600 18600 72700 15000 62300 12500 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-124 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 125 10200 39000 8500 55.0 64200 14300 54100 11600 45400 9500 39000 7900 59.0 67100 14300 54100 11200 45400 9000 39000 7500 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-125 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 126 44800 160800 36300 135000 29800 115700 24800 59.0 199300 45000 160800 35200 135000 28300 115700 23500 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-126 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 438...
  • Page 127 26000 92200 21700 55.0 151800 36600 128000 29700 107500 24300 92200 20200 59.0 158700 36700 128000 28700 107500 23100 92200 19200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-127 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 128 16700 57600 13900 55.0 94900 23400 80000 19000 67200 15600 57600 13000 59.0 99200 23500 80000 18400 67200 14800 57600 12300 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-128 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 129 64000 215300 51900 180800 42500 155000 35400 59.0 266900 64300 215300 50300 180800 40500 155000 33600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-129 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 444...
  • Page 130 35300 123900 29400 55.0 204000 49500 172000 40200 144500 32900 123900 27400 59.0 213300 49800 172000 38900 144500 31300 123900 26000 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-130 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 131 21200 77400 17700 55.0 127500 29800 107500 24200 90300 19800 77400 16500 59.0 133300 29900 107500 23400 90300 18800 77400 15600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-131 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 132 21400 80200 17300 67300 14200 57700 11800 59.0 99400 21500 80200 16800 67300 13500 57700 11200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-132 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 450...
  • Page 133 12400 46000 10400 55.0 75700 17400 63800 14100 53600 11600 46000 9600 59.0 79200 17500 63800 13700 53600 11000 46000 9100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-133 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 134 11200 39900 9100 33500 7400 28700 6200 59.0 49500 11200 39900 8800 33500 7100 28700 5900 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-134 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 452...
  • Page 135 30700 108300 24900 91000 20400 78000 17000 59.0 134300 30800 108300 24100 91000 19400 78000 16100 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-135 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 456...
  • Page 136 16900 62300 14100 55.0 102700 23800 86600 19300 72700 15800 62300 13100 59.0 107400 23900 86600 18600 72700 15000 62300 12500 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-136 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 137 10200 39000 8500 55.0 64200 14300 54100 11600 45400 9500 39000 7900 59.0 67100 14300 54100 11200 45400 9000 39000 7500 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-137 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 138 44800 160800 36300 135000 29800 115700 24800 59.0 199300 45000 160800 35200 135000 28300 115700 23500 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-138 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 462...
  • Page 139 26000 92200 21700 55.0 151800 36600 128000 29700 107500 24300 92200 20200 59.0 158700 36700 128000 28700 107500 23100 92200 19200 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-139 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 140 16700 57600 13900 55.0 94900 23400 80000 19000 67200 15600 57600 13000 59.0 99200 23500 80000 18400 67200 14800 57600 12300 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-140 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 141 64000 215300 51900 180800 42500 155000 35400 59.0 266900 64300 215300 50300 180800 40500 155000 33600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-141 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 468...
  • Page 142 35300 123900 29400 55.0 204000 49500 172000 40200 144500 32900 123900 27400 59.0 213300 49800 172000 38900 144500 31300 123900 26000 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-142 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 143 21200 77400 17700 55.0 127500 29800 107500 24200 90300 19800 77400 16500 59.0 133300 29900 107500 23400 90300 18800 77400 15600 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-143 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 144: Outdoor Temperature

    CITY MULTI could have various capacities at different design temperatures. Using the nominal cooling/heating capacity value and the ratio below, the capacity can be observed at various temperatures. Capacity at 100% indoor units running 15 0 21.1 25.0 25.0 27.2 Outdoor Temperature H2i-R2-144 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 145 To select high-heating performance operation, DipSW3-7 must be set to ON. At low ambient temperatures, heating capacity and power input become higher than those seen in standard operation. Capacity at 100% indoor units running 15 0 15.0 21.1 25.0 25.0 27.2 Outdoor Temperature H2i-R2-145 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 146 CITY MULTI could have various capacities at different design temperatures. Using the nominal cooling/heating capacity value and the ratio below, the capacity can be observed at various temperatures. Capacity at 100% indoor units running 15.0 21.1 25.0 27.2 Outdoor Temperature H2i-R2-146 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 147: Cooling Capacity

    6.22 46.1 14.59 3.77 15.15 4.10 16.27 4.52 17.11 4.54 17.39 4.83 18.37 4.93 19.70 5.03 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-147 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 263 © 2014 Mitsubishi Electric US, Inc.
  • Page 148 6.12 46.1 13.73 3.71 14.26 4.04 15.31 4.44 16.10 4.47 16.37 4.75 17.28 4.85 18.53 4.95 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-148 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 264...
  • Page 149 4.21 46.1 9.61 2.55 9.98 2.78 10.72 3.06 11.27 3.08 11.46 3.27 12.10 3.34 12.97 3.41 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-149 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 265...
  • Page 150 3.13 46.1 6.87 1.90 7.13 2.07 7.66 2.28 8.06 2.29 8.19 2.43 8.65 2.48 9.27 2.54 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-150 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 266...
  • Page 151 9.29 46.1 19.48 5.63 20.22 6.13 21.72 6.75 22.84 6.79 23.22 7.21 24.52 7.36 26.29 7.52 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-151 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 271...
  • Page 152 9.22 46.1 18.29 5.59 18.99 6.09 20.39 6.70 21.45 6.74 21.80 7.16 23.02 7.31 24.68 7.47 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-152 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 272...
  • Page 153 5.92 46.1 12.80 3.59 13.30 3.91 14.28 4.30 15.02 4.33 15.26 4.60 16.12 4.69 17.28 4.79 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-153 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 273...
  • Page 154 4.24 46.1 9.14 2.57 9.49 2.80 10.20 3.08 10.72 3.10 10.90 3.29 11.51 3.36 12.34 3.43 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-154 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 274...
  • Page 155 9.29 46.1 19.48 5.63 20.22 6.13 21.72 6.75 22.84 6.79 23.22 7.21 24.52 7.36 26.29 7.52 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-155 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 271...
  • Page 156 13.28 46.1 29.18 8.05 30.30 8.76 32.55 9.65 34.23 9.70 34.79 10.31 36.74 10.53 39.39 10.75 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-156 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 279...
  • Page 157 13.06 46.1 27.46 7.92 28.52 8.62 30.63 9.49 32.21 9.54 32.74 10.14 34.57 10.36 37.07 10.57 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-157 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 280...
  • Page 158 8.99 46.1 19.22 5.45 19.96 5.94 21.44 6.53 22.54 6.57 22.91 6.98 24.20 7.13 25.94 7.28 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-158 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 281...
  • Page 159 6.69 46.1 13.74 4.06 14.26 4.42 15.32 4.86 16.11 4.89 16.38 5.19 17.29 5.31 18.54 5.42 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-159 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 282...
  • Page 160 19.23 46.1 39.02 11.65 40.52 12.69 43.52 13.97 45.77 14.05 46.52 14.93 49.12 15.25 52.67 15.57 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-160 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 287...
  • Page 161 19.10 46.1 36.64 11.57 38.04 12.60 40.86 13.87 42.97 13.95 43.67 14.82 46.12 15.14 49.45 15.46 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-161 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 288...
  • Page 162 12.26 46.1 25.65 7.43 26.64 8.09 28.61 8.91 30.09 8.96 30.58 9.52 32.29 9.72 34.63 9.92 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-162 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 289...
  • Page 163 8.78 46.1 18.32 5.32 19.02 5.79 20.43 6.38 21.49 6.41 21.84 6.81 23.06 6.96 24.73 7.11 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-163 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 290...
  • Page 164 6.22 46.1 14.59 3.77 15.15 4.10 16.27 4.52 17.11 4.54 17.39 4.83 18.37 4.93 19.70 5.03 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-164 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS © 2014 Mitsubishi Electric US, Inc. 2 - 295...
  • Page 165 6.12 46.1 13.73 3.71 14.26 4.04 15.31 4.44 16.10 4.47 16.37 4.75 17.28 4.85 18.53 4.95 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-165 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 296...
  • Page 166 4.21 46.1 9.61 2.55 9.98 2.78 10.72 3.06 11.27 3.08 11.46 3.27 12.10 3.34 12.97 3.41 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-166 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 297...
  • Page 167 3.13 46.1 6.87 1.90 7.13 2.07 7.66 2.28 8.06 2.29 8.19 2.43 8.65 2.48 9.27 2.54 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-167 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 298...
  • Page 168 9.29 46.1 19.48 5.63 20.22 6.13 21.72 6.75 22.84 6.79 23.22 7.21 24.52 7.36 26.29 7.52 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-168 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 303...
  • Page 169 9.22 46.1 18.29 5.59 18.99 6.09 20.39 6.70 21.45 6.74 21.80 7.16 23.02 7.31 24.68 7.47 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-169 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 304...
  • Page 170 5.92 46.1 12.80 3.59 13.30 3.91 14.28 4.30 15.02 4.33 15.26 4.60 16.12 4.69 17.28 4.79 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-170 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 305...
  • Page 171 4.24 46.1 9.14 2.57 9.49 2.80 10.20 3.08 10.72 3.10 10.90 3.29 11.51 3.36 12.34 3.43 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-171 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 306...
  • Page 172 13.28 46.1 29.18 8.05 30.30 8.76 32.55 9.65 34.23 9.70 34.79 10.31 36.74 10.53 39.39 10.75 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-172 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 311...
  • Page 173 13.06 46.1 27.46 7.92 28.52 8.62 30.63 9.49 32.21 9.54 32.74 10.14 34.57 10.36 37.07 10.57 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-173 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 312...
  • Page 174 8.99 46.1 19.22 5.45 19.96 5.94 21.44 6.53 22.54 6.57 22.91 6.98 24.20 7.13 25.94 7.28 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-174 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 313...
  • Page 175 6.69 46.1 13.74 4.06 14.26 4.42 15.32 4.86 16.11 4.89 16.38 5.19 17.29 5.31 18.54 5.42 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-175 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 314...
  • Page 176 19.23 46.1 39.02 11.65 40.52 12.69 43.52 13.97 45.77 14.05 46.52 14.93 49.12 15.25 52.67 15.57 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-176 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 319...
  • Page 177 19.10 46.1 36.64 11.57 38.04 12.60 40.86 13.87 42.97 13.95 43.67 14.82 46.12 15.14 49.45 15.46 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-177 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 320...
  • Page 178 12.26 46.1 25.65 7.43 26.64 8.09 28.61 8.91 30.09 8.96 30.58 9.52 32.29 9.72 34.63 9.92 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-178 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 321...
  • Page 179 19.10 46.1 36.64 11.57 38.04 12.60 40.86 13.87 42.97 13.95 43.67 14.82 46.12 15.14 49.45 15.46 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-179 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 320...
  • Page 180: Heating Capacity

    6.25 23.51 5.07 19.75 4.14 16.93 3.45 15.0 29.15 6.28 23.51 4.90 19.75 3.92 16.93 3.27 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-180 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 327 © 2014 Mitsubishi Electric US, Inc.
  • Page 181 5.10 18.72 4.13 15.73 3.38 13.48 2.82 15.0 23.21 5.12 18.72 4.00 15.73 3.20 13.48 2.67 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-181 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 328...
  • Page 182 2.33 8.43 1.94 12.8 13.88 3.27 11.70 2.65 9.83 2.16 8.43 1.80 15.0 14.51 3.28 11.70 2.56 9.83 2.05 8.43 1.71 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-182 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 183 9.00 31.74 7.29 26.66 5.96 22.85 4.97 15.0 39.36 9.04 31.74 7.06 26.66 5.65 22.85 4.70 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-183 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 333...
  • Page 184 4.96 18.26 4.14 12.8 30.09 6.96 25.36 5.64 21.31 4.61 18.26 3.85 15.0 31.45 6.99 25.36 5.46 21.31 4.37 18.26 3.64 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-184 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 185 2.98 11.41 2.49 12.8 18.80 4.19 15.85 3.39 13.31 2.77 11.41 2.31 15.0 19.65 4.20 15.85 3.29 13.31 2.63 11.41 2.19 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-185 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 186 13.14 47.12 10.65 39.58 8.71 33.93 7.26 15.0 58.43 13.19 47.12 10.31 39.58 8.25 33.93 6.87 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-186 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 339...
  • Page 187 7.64 27.02 6.38 12.8 44.51 10.72 37.52 8.69 31.52 7.11 27.02 5.92 15.0 46.53 10.77 37.52 8.41 31.52 6.73 27.02 5.60 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-187 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 188 6.87 23.46 5.57 19.71 4.55 16.89 3.79 15.0 29.09 6.90 23.46 5.39 19.71 4.31 16.89 3.59 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-188 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 341...
  • Page 189 18.77 63.08 15.21 52.98 12.44 45.42 10.37 15.0 78.22 18.85 63.08 14.73 52.98 11.78 45.42 9.81 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-189 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 345...
  • Page 190 14.52 50.41 11.77 42.34 9.62 36.29 8.02 15.0 62.51 14.58 50.41 11.39 42.34 9.11 36.29 7.59 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-190 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 346...
  • Page 191 8.73 31.50 7.08 26.46 5.79 22.68 4.82 15.0 39.06 8.77 31.50 6.85 26.46 5.48 22.68 4.56 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-191 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 347...
  • Page 192 6.25 23.51 5.07 19.75 4.14 16.93 3.45 15.0 29.15 6.28 23.51 4.90 19.75 3.92 16.93 3.27 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-192 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 351...
  • Page 193 3.63 13.48 3.03 12.8 22.21 5.10 18.72 4.13 15.73 3.38 13.48 2.82 15.0 23.21 5.12 18.72 4.00 15.73 3.20 13.48 2.67 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-193 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 194 3.27 11.70 2.65 9.83 2.16 8.43 1.80 15.0 14.51 3.28 11.70 2.56 9.83 2.05 8.43 1.71 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-194 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 353...
  • Page 195 9.00 31.74 7.29 26.66 5.96 22.85 4.97 15.0 39.36 9.04 31.74 7.06 26.66 5.65 22.85 4.70 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-195 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 357...
  • Page 196 4.96 18.26 4.14 12.8 30.09 6.96 25.36 5.64 21.31 4.61 18.26 3.85 15.0 31.45 6.99 25.36 5.46 21.31 4.37 18.26 3.64 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-196 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 197 2.98 11.41 2.49 12.8 18.80 4.19 15.85 3.39 13.31 2.77 11.41 2.31 15.0 19.65 4.20 15.85 3.29 13.31 2.63 11.41 2.19 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-197 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 198 13.14 47.12 10.65 39.58 8.71 33.93 7.26 15.0 58.43 13.19 47.12 10.31 39.58 8.25 33.93 6.87 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-198 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 363...
  • Page 199 10.72 37.52 8.69 31.52 7.11 27.02 5.92 15.0 46.53 10.77 37.52 8.41 31.52 6.73 27.02 5.60 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-199 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 364...
  • Page 200 6.87 23.46 5.57 19.71 4.55 16.89 3.79 15.0 29.09 6.90 23.46 5.39 19.71 4.31 16.89 3.59 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-200 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 365...
  • Page 201 18.77 63.08 15.21 52.98 12.44 45.42 10.37 15.0 78.22 18.85 63.08 14.73 52.98 11.78 45.42 9.81 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-201 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 369...
  • Page 202 14.52 50.41 11.77 42.34 9.62 36.29 8.02 15.0 62.51 14.58 50.41 11.39 42.34 9.11 36.29 7.59 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-202 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 370...
  • Page 203 8.73 31.50 7.08 26.46 5.79 22.68 4.82 15.0 39.06 8.77 31.50 6.85 26.46 5.48 22.68 4.56 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-203 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 371...
  • Page 204 9.00 31.74 7.29 26.66 6.05 22.85 5.07 15.0 39.36 9.04 31.74 7.06 26.66 5.92 22.85 4.95 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-204 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 381...
  • Page 205 3.58 13.48 3.01 12.8 22.21 5.10 18.72 4.13 15.73 3.43 13.48 2.87 15.0 23.21 5.12 18.72 4.00 15.73 3.36 13.48 2.81 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-205 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 206 2.29 8.43 1.93 12.8 13.88 3.27 11.70 2.65 9.83 2.19 8.43 1.84 15.0 14.51 3.28 11.70 2.56 9.83 2.15 8.43 1.80 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-206 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 207 9.00 31.74 7.29 26.66 6.05 22.85 5.07 15.0 39.36 9.04 31.74 7.06 26.66 5.92 22.85 4.95 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-207 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 381...
  • Page 208 4.89 18.26 4.11 12.8 30.09 6.96 25.36 5.64 21.31 4.68 18.26 3.92 15.0 31.45 6.99 25.36 5.46 21.31 4.58 18.26 3.83 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-208 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 209 2.94 11.41 2.47 12.8 18.80 4.19 15.85 3.39 13.31 2.81 11.41 2.36 15.0 19.65 4.20 15.85 3.29 13.31 2.76 11.41 2.30 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-209 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 210 13.14 47.12 10.65 39.58 8.83 33.93 7.40 15.0 58.43 13.19 47.12 10.31 39.58 8.65 33.93 7.23 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-210 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 387...
  • Page 211 7.53 27.02 6.33 12.8 44.51 10.72 37.52 8.69 31.52 7.21 27.02 6.04 15.0 46.53 10.77 37.52 8.41 31.52 7.06 27.02 5.90 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-211 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 212 4.82 16.89 4.05 12.8 27.83 6.87 23.46 5.57 19.71 4.61 16.89 3.87 15.0 29.09 6.90 23.46 5.39 19.71 4.52 16.89 3.78 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-212 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 213 18.77 63.08 15.21 52.98 12.61 45.42 10.58 15.0 78.22 18.85 63.08 14.73 52.98 12.35 45.42 10.32 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-213 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 393...
  • Page 214 10.19 36.29 8.57 12.8 59.79 14.52 50.41 11.77 42.34 9.76 36.29 8.18 15.0 62.51 14.58 50.41 11.39 42.34 9.56 36.29 7.98 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-214 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 215 6.13 22.68 5.15 12.8 37.36 8.73 31.50 7.08 26.46 5.87 22.68 4.92 15.0 39.06 8.77 31.50 6.85 26.46 5.75 22.68 4.80 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-215 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 216 6.25 23.51 5.07 19.75 4.20 16.93 3.52 15.0 29.15 6.28 23.51 4.90 19.75 4.11 16.93 3.44 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-216 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 399...
  • Page 217 3.58 13.48 3.01 12.8 22.21 5.10 18.72 4.13 15.73 3.43 13.48 2.87 15.0 23.21 5.12 18.72 4.00 15.73 3.36 13.48 2.81 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-217 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 218 2.29 8.43 1.93 12.8 13.88 3.27 11.70 2.65 9.83 2.19 8.43 1.84 15.0 14.51 3.28 11.70 2.56 9.83 2.15 8.43 1.80 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-218 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 219 9.00 31.74 7.29 26.66 6.05 22.85 5.07 15.0 39.36 9.04 31.74 7.06 26.66 5.92 22.85 4.95 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-219 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 405...
  • Page 220 4.89 18.26 4.11 12.8 30.09 6.96 25.36 5.64 21.31 4.68 18.26 3.92 15.0 31.45 6.99 25.36 5.46 21.31 4.58 18.26 3.83 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-220 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 221 2.94 11.41 2.47 12.8 18.80 4.19 15.85 3.39 13.31 2.81 11.41 2.36 15.0 19.65 4.20 15.85 3.29 13.31 2.76 11.41 2.30 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-221 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 222 13.14 47.12 10.65 39.58 8.83 33.93 7.40 15.0 58.43 13.19 47.12 10.31 39.58 8.65 33.93 7.23 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-222 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 411...
  • Page 223 7.53 27.02 6.33 12.8 44.51 10.72 37.52 8.69 31.52 7.21 27.02 6.04 15.0 46.53 10.77 37.52 8.41 31.52 7.06 27.02 5.90 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-223 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 224 4.82 16.89 4.05 12.8 27.83 6.87 23.46 5.57 19.71 4.61 16.89 3.87 15.0 29.09 6.90 23.46 5.39 19.71 4.52 16.89 3.78 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-224 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 225 18.77 63.08 15.21 52.98 12.61 45.42 10.58 15.0 78.22 18.85 63.08 14.73 52.98 12.35 45.42 10.32 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-225 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 417...
  • Page 226 10.19 36.29 8.57 12.8 59.79 14.52 50.41 11.77 42.34 9.76 36.29 8.18 15.0 62.51 14.58 50.41 11.39 42.34 9.56 36.29 7.98 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-226 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 227 6.13 22.68 5.15 12.8 37.36 8.73 31.50 7.08 26.46 5.87 22.68 4.92 15.0 39.06 8.77 31.50 6.85 26.46 5.75 22.68 4.80 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-227 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 228 6.25 23.51 5.07 19.75 4.15 16.93 3.45 15.0 29.15 6.28 23.51 4.90 19.75 3.95 16.93 3.28 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-228 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 423 © 2014 Mitsubishi Electric US, Inc.
  • Page 229 3.63 13.48 3.03 12.8 22.21 5.10 18.72 4.13 15.73 3.39 13.48 2.82 15.0 23.21 5.12 18.72 4.00 15.73 3.22 13.48 2.67 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-229 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 230 2.32 8.43 1.94 12.8 13.88 3.27 11.70 2.65 9.83 2.17 8.43 1.81 15.0 14.51 3.28 11.70 2.56 9.83 2.06 8.43 1.71 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-230 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 231 9.00 31.74 7.29 26.66 5.98 22.85 4.98 15.0 39.36 9.04 31.74 7.06 26.66 5.69 22.85 4.72 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-231 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 429...
  • Page 232 4.95 18.26 4.14 12.8 30.09 6.96 25.36 5.64 21.31 4.62 18.26 3.85 15.0 31.45 6.99 25.36 5.46 21.31 4.40 18.26 3.65 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-232 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 233 2.98 11.41 2.49 12.8 18.80 4.19 15.85 3.39 13.31 2.78 11.41 2.31 15.0 19.65 4.20 15.85 3.29 13.31 2.64 11.41 2.19 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-233 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 234 13.14 47.12 10.65 39.58 8.73 33.93 7.26 15.0 58.43 13.19 47.12 10.31 39.58 8.30 33.93 6.89 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-234 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 435...
  • Page 235 7.63 27.02 6.37 12.8 44.51 10.72 37.52 8.69 31.52 7.12 27.02 5.93 15.0 46.53 10.77 37.52 8.41 31.52 6.77 27.02 5.62 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-235 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 236 4.89 16.89 4.08 12.8 27.83 6.87 23.46 5.57 19.71 4.56 16.89 3.80 15.0 29.09 6.90 23.46 5.39 19.71 4.34 16.89 3.60 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-236 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 237 18.77 63.08 15.21 52.98 12.47 45.42 10.38 15.0 78.22 18.85 63.08 14.73 52.98 11.86 45.42 9.84 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-237 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 441...
  • Page 238 10.33 36.29 8.63 12.8 59.79 14.52 50.41 11.77 42.34 9.64 36.29 8.03 15.0 62.51 14.58 50.41 11.39 42.34 9.17 36.29 7.61 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-238 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 239 6.21 22.68 5.19 12.8 37.36 8.73 31.50 7.08 26.46 5.80 22.68 4.83 15.0 39.06 8.77 31.50 6.85 26.46 5.52 22.68 4.58 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-239 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 240 6.25 23.51 5.07 19.75 4.15 16.93 3.45 15.0 29.15 6.28 23.51 4.90 19.75 3.95 16.93 3.28 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-240 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 447...
  • Page 241 5.10 18.72 4.13 15.73 3.39 13.48 2.82 15.0 23.21 5.12 18.72 4.00 15.73 3.22 13.48 2.67 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-241 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 448...
  • Page 242 2.32 8.43 1.94 12.8 13.88 3.27 11.70 2.65 9.83 2.17 8.43 1.81 15.0 14.51 3.28 11.70 2.56 9.83 2.06 8.43 1.71 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-242 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 243 9.00 31.74 7.29 26.66 5.98 22.85 4.98 15.0 39.36 9.04 31.74 7.06 26.66 5.69 22.85 4.72 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-243 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 453...
  • Page 244 4.95 18.26 4.14 12.8 30.09 6.96 25.36 5.64 21.31 4.62 18.26 3.85 15.0 31.45 6.99 25.36 5.46 21.31 4.40 18.26 3.65 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-244 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 245 2.98 11.41 2.49 12.8 18.80 4.19 15.85 3.39 13.31 2.78 11.41 2.31 15.0 19.65 4.20 15.85 3.29 13.31 2.64 11.41 2.19 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-245 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 246 13.14 47.12 10.65 39.58 8.73 33.93 7.26 15.0 58.43 13.19 47.12 10.31 39.58 8.30 33.93 6.89 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-246 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 459...
  • Page 247 7.63 27.02 6.37 12.8 44.51 10.72 37.52 8.69 31.52 7.12 27.02 5.93 15.0 46.53 10.77 37.52 8.41 31.52 6.77 27.02 5.62 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-247 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 248 4.89 16.89 4.08 12.8 27.83 6.87 23.46 5.57 19.71 4.56 16.89 3.80 15.0 29.09 6.90 23.46 5.39 19.71 4.34 16.89 3.60 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-248 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 249 18.77 63.08 15.21 52.98 12.47 45.42 10.38 15.0 78.22 18.85 63.08 14.73 52.98 11.86 45.42 9.84 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-249 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc. OUTDOOR UNITS 2 - 465...
  • Page 250 10.33 36.29 8.63 12.8 59.79 14.52 50.41 11.77 42.34 9.64 36.29 8.03 15.0 62.51 14.58 50.41 11.39 42.34 9.17 36.29 7.61 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-250 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 251 6.21 22.68 5.19 12.8 37.36 8.73 31.50 7.08 26.46 5.80 22.68 4.83 15.0 39.06 8.77 31.50 6.85 26.46 5.52 22.68 4.58 kcal/h=kW x 860 , BTU/h = kW x 3,412 H2i-R2-251 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 252: Cooling Capacity Correction

    0.90 0.85 0.80 100 150 200 250 300 350 400 450 500 550 600 92 107 122 137 153 168 183 m Piping equivalent length H2i-R2-252 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) OUTDOOR UNITS 2 - 471 © 2014 Mitsubishi Electric US, Inc.
  • Page 253 Equivalent length = (Actual piping length to the farthest indoor unit ) + (1.64 x number of bent on the piping) [ft.] Equivalent length = (Actual piping length to the farthest indoor unit ) + (0.50 x number of bent on the piping) [m] H2i-R2-253 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 254 Correction factor for a full load and above : K Partial load factor : A K = 1 - ( 1 - K ) × A OUTDOOR UNITS 2 - 473 H2i-R2-254 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 255: Operation Temperature Range

    59 to 75 FWB (15 to 24 CWB) Installation of the low ambient kit is recommended to operate in cooling and cooling main mode in conditions under 50°F [10°C]. OUTDOOR UNITS 2 - 474 H2i-R2-255 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 256 (25 kg) (28 kg) (1,092 x 914 x 775 mm) (P120 and P144) modules Manufactured for Mitsubishi Electric and Electronics USA Side Wind Deflector, includes 2 pieces (fits all 45 lbs. 50 lbs. 54" L x 20" W x 9" H...
  • Page 257: Optional Parts

    8-1. Branch Joints Piping for CITY MULTI systems can be easily performed with branch joints and headers provided by Mitsubishi Electric Corp. For PURY-HP-T(S)KMU/Y(S)KMU, three sets of branch joints are available. Details for installing the branch joint sets are found in the System Design section or in the Branch Joint Installation Manual.
  • Page 258 2. Use the attached pipe to braze the port-opening of the distributer. 3. Pipe diameter is indicated by inside diameter. 4. Only use the Twinning pipe by Mitsubishi (optional parts) . H2i-R2-258 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 259 Clamping torque 80N•m Use two spanners simultaneously for tightening. Coat the flare contact surface with refrigerating machine oil. Joint pipe(for gas side) Fig.2. Connecting CMY-R160C-J OUTDOOR UNITS 2 - 477 H2i-R2-259 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 260: Low Ambient Kit

    Component Quantity Unit model LAHK-1 LAHK-2 SWDK-1 RWDK-1 RWDK-2 PURY-HP72TKMU-A-H PURY-HP96TKMU-A-H PURY-HP144TSKMU-A-H PURY-HP192TSKMU-A-H PURY-HP-Y(S)KMU-A Series Module Size Component Quantity Unit model LAHK-1 LAHK-2 SWDK-1 RWDK-1 RWDK-2 PURY-HP72YKMU-A PURY-HP96YKMU-A PURY-HP144YSKMU-A PURY-HP192YSKMU-A H2i-R2-260 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 261 Dimensions PUHY-P360(T,Y)SKMU-A Wind Deflectors SWDK-1, RWDK-1 and RWDK-2 Wind Deflectors SWDK-1, RWDK-1 and RWDK-2. Manufactured for Mitsubishi Electric and Electronics USA Manufactured for Mitsubishi Electric and Electronics USA Dimensions Dimensions Low Ambient Hood LAHK-1 (used alone for single fan modules P72 and P96 sizes).
  • Page 262 MGM PRODUCTS , INC. COMPANY : PROJECT : 1080 CULPEPPER DRIVE CONYERS, GA. 30094 APPROVAL : ARCHITECT : PHONE : 770-483-0055 800-341-3536 FAX : 770-483-0130 P.O. NUMBER : ENGINEER : H2i-R2-262 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 263 Module Size Component Qty Unit model SGK-1 SGK-2 SGK-3 SHK-1 PURY-HP72TKMU-A-H PURY-HP96TKMU-A-H PURY-HP144TSKMU-A-H PURY-HP192TSKMU-A-H PURY-HP-Y(S)KMU-A Series Module Size Component Qty Unit model SGK-1 SGK-2 SGK-3 SHK-1 PURY-HP72YKMU-A PURY-HP96YKMU-A PURY-HP144YSKMU-A PURY-HP192YSKMU-A H2i-R2-263 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 264 8. OPTIONAL PARTS Dimensions Snow/Hail Guards SGK-1 (2 PER KIT) H2i-R2-264 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 265 8. OPTIONAL PARTS DIMENSIONAL DATA Dimensions Snow/Hail Guards SHK-1 SHK-1 SHK-1 SGK-1 SGK-1 H2i-R2-265 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.
  • Page 266 H2i-R2-266 PURY-HP-T(S)KMU,-Y(S)KMU (September 2014) © 2014 Mitsubishi Electric US, Inc.

Table of Contents