OPERATING INSTRUCTIONS
If heater shuts off, do not relight until you pro-
vide fresh air. If heater keeps shutting off, have it
serviced. Keep burner and control compartment
clean.
WARNING:
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. This fi replace is equipped with a pilot which must be lit
by hand while following these instructions exactly.
B. Before operating smell all around the fi replace area for
gas and next to the fl oor because some gas is heavier
than air and will settle on the fl oor.
C. Use only your hand to push in and turn the gas control
knob. Never use tools. If the knob will not push in and
turn by hand, do not try to repair it. Call a qualifi ed service
technician. Force or attempted repair may result in a fi re
or explosion.
D. Do not use this fi replace if any part has been under water.
Immediately call a qualifi ed service technician to inspect
the fi replace and replace any part of the control system
and any gas control which has been under water.
• Do not try to light any appliance.
1. STOP! Read the above safety information on this label.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the fi replace.
4. Open the control door. Turn the gas knob clockwise
to off.
5. Wait fi ve (5) minutes to clear out any gas. If you smell gas
including near the fl oor, STOP! Follow "B" in the above
safety information on this label. If you don't smell gas go
to the next step.
6. Find pilot located in front of the back log.
7. Turn gas knob counter-clockwise
8. Depress and hold gas knob while lighting the pilot with
the push button ignitor. Keep knob fully depressed for one
minute, then release. If pilot does not continue to burn
repeat steps 3 through 7.
9. With pilot lit, turn gas knob counter-clockwise
When the pilot has been turned off, ignition of the main
1. Turn off all electric power to the fi replace if service is to
be performed.
W415-0559 / 02.15.06

OPERATION

FOR YOUR SAFETY READ BEFORE LIGHTING:
LIGHTING INSTRUCTIONS
to pilot.
to on.
TO TURN OFF GAS
When lit for the fi rst time, the fi replace will emit a slight odour
for a few hours. This is a normal temporary condition caused
by the curing of the logs and the "burn-in" of internal paints
and lubricants used in the manufacturing process and will not
occur again. After extended periods of non-operation such as
following a vacation or a warm weather season, the fi replace
may emit a slight odour for a few hours. This is caused by
dust particles burning off. In both cases, open a window to
suffi ciently ventilate the room.
WHAT TO DO IF YOU SMELL GAS:
• Do not touch any electric switch; do not use any phone
in your building.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fi re de-
partment.
When lighting and re-lighting, the gas knob cannot be turned
from pilot to off unless the knob is depressed.
OXYGEN DEPLETION SENSOR
burner may be delayed from 1-2 minutes.
When the pilot has been left burning, ignition of the main
burner should occur almost immediatley.
10. If equipped with remote on-off switch, main burner may
not come on when you turn the valve to on. Remote switch
must be in the on position to ignite burner.
11. Turn on all electric power to the fi replace.
2. Push in gas control knob slightly and turn clockwise
to off. Do not force.
GAS KNOB
GAS KNOB AT OFF

Advertisement