OPERATION / MAINTENANCE

Purge all gas lines with the glass door of the fi replace removed or
opened. Assure that a continuous gas fl ow is at the burner before
installing the door.
When lit for the fi rst time, the fi replace will emit a slight odour by the
"burn-in" of internal paints and lubricants used in the manufacturing
process and will not occur again.
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
A. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE
WHICH AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY TO LIGHT
BY HAND.
B. BEFORE OPERATING SMELL ALL AROUND THE FIREPLACE
AREA FOR GAS AND NEXT TO THE FLOOR BECAUSE SOME GAS IS
HEAVIER THAN AIR AND WILL SETTLE ON THE FLOOR.
C. USE ONLY YOUR HAND TO TURN THE GAS CONTROL KNOB.
NEVER USE TOOLS. IF THE KNOB WILL NOT TURN BY HAND, DO NOT
TRY TO REPAIR IT. CALL A QUALIFIED SERVICE TECHNICIAN. FORCE
OR ATTEMPTED REPAIR MAY RESULT IN A FIRE OR EXPLOSION.
D. DO NOT USE THIS FIREPLACE IF ANY PART HAS BEEN UNDER
WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN
TO INSPECT THE FIREPLACE AND REPLACE ANY PART OF THE
CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN
UNDER WATER.
1. STOP! READ THE ABOVE SAFETY INFORMATION ON
THIS LABEL.
2. TURN REMOTE WALL SWITCH TO OFF POSITION.
3. TURN OFF ALL ELECTRIC POWER TO THE FIREPLACE
AND REMOVE BATTERIES.
4. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION
DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT. DO
NOT TRY TO LIGHT THE PILOT BY HAND.
5. TURN MANUAL SHUTOFF VALVE CLOCKWISE
OFF.
6. OPEN THE GLASS DOOR.
7. WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS. IF
YOU SMELL GAS INCLUDING NEAR THE FLOOR, STOP!
FOLLOW "B" IN THE ABOVE SAFETY INFORMATION ON
THIS LABEL. IF YOU DON'T SMELL GAS GO TO THE
NEXT STEP.
1. TURN OFF REMOTE WALL SWITCH TO THE FIREPLACE.
2. TURN OFF ALL ELECTRICAL POWER TO THE FIREPLACE IF SERVICE IS TO BE PERFORMED.
3. TURN MANUAL SHUTOFF VALVE CLOCKWISE
TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER
BEFORE SERVICING THE STOVE:
Caution: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing. This stove and its venting
system should be inspected before use and at least annually by a
qualifi ed service person. The fi replace area must be kept clear and
free of combustible materials, gasoline or other fl ammable vapours
and liquids. The fl ow of combustion and ventilation air must not be
obstructed.
1. In order to properly clean the burner and pilot assembly, remove
the logs exposing both assemblies.
2. Keep the control compartment, logs, burner, air shutter opening
and the area surrounding the logs clean by vacuuming or brushing,
at least once a year.
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING
!
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

OPERATING INSTRUCTIONS

TO
TO TURN OFF GAS
TO OFF. DO NOT FORCE.

MAINTENANCE

After extended periods of non-operation such as following a vacation
or a warm weather season, the fi replace may omit a slight odour for
a few hours. This is caused by dust particles in the heat exchanger
burning off. In both cases, open a window to suffi ciently ventilate
the room.
WHAT TO DO IF YOU SMELL GAS:
TURN OFF ALL GAS TO THE FIREPLACE.
OPEN WINDOWS.
DO NOT TRY TO LIGHT ANY APPLIANCE.
DO NOT TOUCH ANY ELECTRIC SWITCH; DO NOT USE ANY
PHONE IN YOUR BUILDING.
IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A
NEIGHBOUR'S PHONE FOLLOW THE GAS SUPPLIER'S
INSTRUCTIONS.
IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE
DEPARTMENT.
8. CLOSE THE GLASS DOOR.
9. TURN MANUAL SHUTOFF VALVE COUNTER-
CLOCKWISE
TO ON.
10. TURN ON ALL ELECTRIC POWER TO THE FIREPLACE
AND RE-INSTALL BATTERIES.
11. TURN ON REMOTE WALL SWITCH TO ON POSITION.
12. IF FIREPLACE WILL NOT OPERATE, FOLLOW
INSTRUCTIONS "TO TURN OFF GAS" AND CALL YOUR
SERVICE TECHNICIAN OR GAS SUPPLIER.
3. Check to see that all burner ports are burning. Clean out any of
the ports which may not be burning or are not burning properly.
4. Check to see that the pilot fl ames are large enough to engulf the
sensor on one leg and reaches toward the burner on the other leg.
5. Replace the cleaned logs.
6. Check to see that the main burner ignites completely on all
openings when the gas knob for the burner is turned on.
A 5-10 second total light-up period is satisfactory. If ignition takes
longer, consult your Napoleon® dealer/distributor.
7. Check that the door gasketing is not broken or missing.
8. If for any reason the vent air intake system is disassembled,
re-install and re-seal per the instructions provided for the initial
installation.
29
Manual Shut-off Valve
Shown in "OFF"
position.
W415-0612 / C / 01.25.08