Wiring Diagram - Napoleon Vittoria GD19N Installation And Operation Instructions Manual

Vented natural & propane gas fireplace
Table of Contents

Advertisement

28
The main burner and Night Light
lower access panel. For ease of accessibility, optional re-
mote wall switches may be installed in a convenient location
for both burner and light operation.
The recommended maximum lead length depends on wire
size:
WIRE SIZE
14 gauge
16 gauge
18 gauge
FIGURE 63
N
: W
OTE
IRE TAGS
ARE BRACKETED
B
ATTERY
H
OLDER
AC A
Main Burner Switch
Brown
(SWI)
To Optional
Wall Switch
(GD-660)
Red
(+)
W415-0612 / C / 01.25.08

WIRING DIAGRAM

switch is located behind
TM
MAX. LENGTH
100 feet
60 feet
40 feet
Black
M
AIN
B
S
URNER
WITCH
Red
B
ATTERY
R
ELAY
Red (3 Volt)
DAPTOR
Black (12 Volt)
To Accent Light &
Night Light
M
ODULE
Black
P
LUG
(-)
Black
(TP)
Yellow
Black
Blue
R
ELAY
P
LUG
Route 2-strand (solid core) wire through the electrical hole
located at the bottom left side of the unit. Connect the wires
from the main burner wall switch to the two corresponding
spade connectors on the back of the on/off switch for the
burner located behind the lower access panel.
connecting the wires to the Night Light
remote operation.
I
GNITION
M
ODULE
Yellow
(S)
Orange
(I)
*
W
IRE
H
ARNESS
*
Switch
TM
Orange
Black
Green
Orange x2
(THTP)
Green x2
(TH)
* See detail for optional
wall switch GD-660 wiring.
TM
on/off switch for
P
ILOT
A
SSEMBLY
[through
Gas line
conduit]
[through
independent
conduit]
P
ILOT
G
L
AS
INE
G
V
AS
ALVE
Repeat

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vittoria gd19p

Table of Contents