Rating Plate Information - Napoleon GDS60N Installation And Operating Instructions Manual

Vented natural and propane gas fireplace heaters
Table of Contents

Advertisement

When the appliance is installed at elevations above 4,500ft, and in the absence of specifi c recommendations from the
local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of 4% for each ad-
ditional 1,000ft.
Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in propane.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
GDS60 - This appliance is not approved for closet or recessed installations. It is approved for bathroom, bed-
room and bedsitting room installations. This appliance may be installed in an aftermarket permanently located,
manufactured (mobile) home, where not prohibited by local codes. (Rear vent) This application requires
changing the main burner orifi ce.
GS60 - This appliance is approved for bedroom and bed-sitting room installations.
2.4

RATING PLATE INFORMATION

MODEL NATURAL GAS/GAZ NATURAL
DIRECT VENT
TOP VENT REAR VENT
0-4500
35,000
21,000
24,500
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.
(LP)
PRESSION AU COLLECTEUR: 3.5" (GN) / 10" (PG) D'UNE COL-
ONNE DÉAU
MIN SUPPLY PRESSURE: 4.5" W.C. (NG) / 11" (LP)
PRESSION D'ALIMENTATION MIN: 4.5" (GN) / 11" (PG) D'UNE
COLONNE D'EAU
MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 7" (GN) / 13" (PG) D'UNE
COLONNE D'EAU
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULE-
MENT AVEC CETTE UNITE.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE,
WHICH WILL COME IN CONTACT WITH THE
FLAMES, OTHER THAN THAT SUPPLIED BY THE
MANUFACTURER WITH THE APPLIANCE.
MODEL CS600/GS60
APPROVED FOR BEDROOM, & BEDSITTING ROOM INSTALLATION. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A
COUCHER, & UN STUDIO. THIS APPLIANCE MUST BE INSTALLED USING AN ADAPTER KIT GS-150KT. CET APPAREIL DOIT ETRE
INSTALLE EN UTILISANT UN ENSEMBLE ADAPTATEUR GS-150KT.
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to the
model, venting and gas type of the unit.
For rating plate location, see "INSTALLATION OVERVIEW" section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
CERTIFIED UNDE :
VENT AND CSA2.22b-2009,ANSI Z21.50b-2009 VENTED G AS FIREPLACE AS A B-VENT. HOMOLOGUE SELON
LES NORMES: CSA 2.33-2009, ANSI Z21.88-2009 FOYER DE CHAUFFAGE AU GAZ AVEC EVACUATION EN
TANT QU'UNE EVACUATION DIRECTE ET CSA2.22b-2009, ANSI Z21.50b-2009 FOYER AU GAZ AVEC EVACUA-
TION EN TANT QU'UN EVENT "B".
NOT FOR USE WITH SOLID FUEL
UN COMBUSTIBLE SOLIDE NE DOIT
PAS ETRE UTILISE AVEC CET APPAREIL
B-VENT
GDS60N
GS60N
CDVS600N
CS600N
0-4500
0-4500
ALTITUDE (FT/PI) ELEVATION
*
21,000
35,000
INPUT (BTU/H) ALIMENTATION
*
12,000
21,000
REDUCED INPUT (BTU/H) ALIMENTATION REDUITE
*
14,700
OUTPUT (BTU/H) RENDEMENT
*
WHEN VENTING OFF THE REAR OF THE UNIT AND TERMINATING HORIZONTALLY
ONLY
L . Y
ULE-
SITTING ROOM
PLIANCE
ST BE INSTA
T LL
MBLE AD
T TEUR
TA
A
GS-150KT.
VENTED GAS FIREPLACE HEATER AS A DIRECT
MODEL PROPANE/PROPANE MODÈLE
LE
B-VENT
DIRECT VENT
GS60P
GDS60P
0P
CS600P
CDVS600P
DVS600P
REAR VENT
NT
TOP VENT
TOP VENT
0-4500
0-4500
0-4500
0-4500
0-4500
*
31,500
21,000
21,000
31,500
31,500
*
22,000
13,000
000
22,000
22,000
*
*
14,700
14,700
22,050
22,050
ONTA
T LLY
L
OPTIONALBLOWER KIT / ENSEMBLE DE
R
SEMBLE DE
VENTILATEUR FACULTATIF: GS64-KT
FACULTA
T
S64-KT
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL AUCUN
MENT: N'AJOUT
P S A CE APPA
PA
P REIL AU
MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES
U DEVA
V NT ENTRER EN CONTA
T C AVEC
A
LES
AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR
UE CELUI QUI EST FOURNI AVEC
A
T APP
LE FABRICANT.
NT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL / DEGAGE-
ARANCE TO COMBUSTIBLE MA
MENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
X DES MATER
A
UX COMBU
A A
A
6"
B
B
6"
C
C
2"
2"
20" TO CEILING FROM
20" TO CEILING FROM STOVE TOP
VE TOP
1" TO DIRECT VENT AND B
1" TO DIRECT VENT AND B-VENT / L'EVACUATION DIRECTE &
N
L'EVA
L'EVACUATION B
V
ATION
A
B
6" TO
6" TO C-VENT/ A L'EVACUATION C
VENT/ A L'EVA
V CUA
20" ENTRE LE DESSUS
20" ENTRE LE DESSUS DU FOYER ET LE PLAFOND
ELECTRICAL RATING/CLASS: 115V 1.5AMP 60HZ
ELECTRICAL R
N. HOMOLO
USING AN
MODEL CDVS600/GDS60 APPROVED FOR BEDROOM, BATHROOM & BEDSIT-
S600/GDS60
PROVED FO
D
TING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF
M INSTALLATION. SUITAB
R MOB
INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH
ACCORDANCE WITH
URRENT ST
SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED
QUIPPED MOBI
OMES, IN CA
STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD,
F CTURED HOME CONTRUC
FA
TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE
280. WHEN THIS US STA
T
THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
RE SAFETY CRIT
INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A.
IN
D COMMUNIT
HOM
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE
T
LATION
SALLE
SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE
N STUD
AP
MAISON M
MAISON MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA
SON INSTA
T
NORME CAN
NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ,
A Z240MH SE
EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE
EN VIGUEUR AU CANADA O
ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR,
T DE CONSTRUCTION
SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT
TION 3280. DANS
ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE
APPLIQUEE
MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS
S DE S
DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES,
MA
ANSI/NFPA 501A.
AFUE: 64%
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20
FEET RESPECTIVELY FOR TOP VENTED UNITS AND 13 INCHES AND 20 FEET
RESPECTIVELY FOR REAR VENTED UNITS. LES LONGUEURS HORIZONTALES
MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS RESPECTIVEMENT
POUR UN EVACUATION VERTICALE ET 13 POUCES ET 20 PIEDS RESPECTIVE-
MENT POUR UN EVACUATION HORIZONTALE.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON
VENT KITS. SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS.
PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING
THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION
PROPRE A NAPOLEON. REFERER AU MANUEL D'INSTALLATION DE PROPRI-
ETAIRE POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REIN-
STALLER ET RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU
SYSTEME DE PRISE D'AIR.
SERIAL NUMBER
GDS60
NO. DE SERIE
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 4Y4 CANADA
7
W385-0459 / B
W415-0788 / B / 11.03.10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs60nGds60pGs60p

Table of Contents