Napoleon GDS60-N Installation And Operation Instructions Manual
Napoleon GDS60-N Installation And Operation Instructions Manual

Napoleon GDS60-N Installation And Operation Instructions Manual

Vented natural and propane gas fireplace heater

Advertisement

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS
INSTALLATION AND OPERATION INSTRUCTIONS FOR:
NATURAL GAS MODELS
PROPANE GAS MODELS
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Do not store or use gasoline or other flammable vapours and liquids in the vicin-
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your build
ing.
Installation and service must be performed by a qualified installer, service
VENTED GAS FIREPLACE HEATER
GDS60-N
GDS60-P
Model GS60 is made up of Model GDS60 and the Adapter Kit GS-150KT
FOR YOUR SAFETY
ity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Immediately call your gas supplier
• If you cannot reach your gas supplier,
agency or the gas supplier.
GS60-N
and
GS60-P
and
from a neighbour's phone. Follow the
gas supplier's instructions.
call the fire department.
1
W415-0158 / E / 02.19.04

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon GDS60-N

  • Page 1 • Do not touch any electrical switch. • Do not use any phone in your build ing. Installation and service must be performed by a qualified installer, service agency or the gas supplier. GDS60-N GS60-N GDS60-P GS60-P FOR YOUR SAFETY •...
  • Page 2: Table Of Contents

    TABLE of CONTENTS Pg 2-4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts Shipping Bracket LOCATION & CLEARANCES 6-12 DIRECT VENT SPECIFICS MODEL GDS60 Vent Lengths/Air Terminal Locations Special Installation Example Offset Installation Example Horizontal Terminations Orifice Replacement Top Vent to Rear Vent Modification Venting Parameters...
  • Page 3: Warranty

    NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station. The complete fireplace is test-fired and thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from NAPOLEON NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY...
  • Page 4: General Instructions

    GENERAL INSTRUCTIONS THIS GAS STOVE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifics that apply to your area, for example: in Massachusetts State: •...
  • Page 5: Location & Clearances

    LOCATION & CLEARANCES Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the stove. Never obstruct the front opening of the stove. GDS60 AND GS60 As long as clearance to combustibles is kept within the required distances, the most desirable and beneficial lo- cation for a Napoleon stove is in the centre of a building, thereby allowing the most efficient use of the heat created.
  • Page 6: Direct Vent Specifics Model Gds60

    DIRECT VENT SPECIFICS - MODEL GDS60 VENTING LENGTHS & AIR TERMINAL LOCATIONS Use only Wolf Steel or Simpson Dura-Vent Model DV-GS venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air termi- nal locations for either system are set out in this manual and must be adhered to.
  • Page 7: Feet

    AIR TERMINAL INSTALLATIONS FIGURE 8 INSTALLATIONS CANADIAN U.S.A. 12 INCHES 12 INCHES 12 INCHES 9 INCHES 12 INCHES* 12 INCHES* 18 INCHES** 18 INCHES** 12 INCHES** 12 INCHES** 0 INCHES 0 INCHES 0 INCHES*** 0 INCHES*** 2 INCHES*** 2 INCHES*** 3 FEET 3 FEET**** 3 FEET...
  • Page 8: Special Installation Example

    SPECIAL INSTALLATION EXAMPLE When a horizontal offset is required in a through-the-roof installation, the following procedure for vent length calcula- tions must be followed: In an installation as shown in FIGURES 9 & 12, lengths A and C are known based on room height and roof require- ments.
  • Page 9: Orifice Replacement

    REAR VENT HORIZONTAL TERMINATION When venting off the rear of the unit and terminating horizontally, a #45 natural gas orifice or a #55 propane orifice must be used. FIGURE 14a The maximum allowable length is 20 feet. All 90° and 45° elbows (except the first two when venting horizontally) re- duce the length by 5 feet each, both horizontally and verti- cally).
  • Page 10: Venting Parameters

    VENTING PARAMETERS WALL & CEILING PROTECTION FOR SAFE AND PROPER OPERATION OF THE STOVE, FIGURES 18a-d FOLLOW THE VENTING INSTRUCTIONS EXACTLY. FIGURE 19 HORIZONTAL INSTALLATION CORNER INSTALLATION This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum square or round opening of 9".
  • Page 11: Horizontal Venting Installation

    VERTICAL INSTALLATION This application occurs when venting through a roof. Installation kits for vari- ous roof pitches are available from your Na- poleon dealer. See Ac- cessories to order the specific kit required. 1. Determine the air terminal location and move the stove into position.
  • Page 12: Vertical Venting Installation

    VERTICAL VENTING INSTALLATION 1. Fasten the roof support to the roof us- ing the screws pro- vided. The roof support is optional. In this case the venting is to be ad- equately supported us- ing either an alternate method suitable to the authority having juris- diction or the optional roof support.
  • Page 13: B-Vent Specifics Model Gs60

    B-VENT SPECIFICS - MODEL GS60 CHIMNEY INSTALLATION THREE TYPES OF CHIMNEY SYSTEMS MAY BE USED WITH THIS STOVE: FIGURES 29 INSTALLING 'B' VENT: Follow the instructions of the 'B' vent manufacturer for chim- ney installation. 1. Remove the access plate. Remove and discard the air intake cover plate located directly behind the access plate.
  • Page 14: Gas Installation

    ADDING VENT SECTIONS For ease of assembly, a 7" telescop- ing stove pipe may be installed over the 4" vent connection of the adapter. Add vent sections, twist locking (clockwise) securely, to the required height. The vent should extend, at least, 3 feet above its point of con- tact with the roof and, at least, 2 feet higher than any wall, roof or build-...
  • Page 15: Finishing

    FINISHING LOGO PLACEMENT Remove the backing of the logo supplied and centre over the logo installation holes, as indicated. FIGURE 37 FIGURE 38b FIGURE 38c HANDLE LOGO RETAINER 'T' LATCH FRONT CAST INSTALLATION FRONT 1. Lift the top casting off the unit. RIDGE 2.
  • Page 16: Log Placement

    LOG PLACEMENT Blocked burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition. PHAZER when exposed to direct flame and provide a unique and realistic glowing effect. Use only certified PHAZER available from your Napoleon dealer. FIGURE 39a-d Place log #1 onto the burner, centering it onto the burner tray and pushing it as close to the rear wall of the firebox as possible.
  • Page 17: Operation / Maintenance

    OPERATION / MAINTENANCE PURGE ALL GAS LINES WITH THE GLASS DOOR OPEN. ASSURE THAT A CONTINUOUS GAS FLOW IS AT THE BURNER BEFORE CLOSING THE DOOR. ALLOW SEVERAL MINUTES (5-15) FOR THE FLAME TO STABILIZE AFTER IGNITION. MODEL GS60 ONLY: SPILL SWITCH This is a thermally activated switch, attached to the back of the chimney adapter, which senses the change in...
  • Page 18: Maintenance

    WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermo- couple has cooled. Allow approximately 60 seconds for the thermocouple to cool before attempting to re-light. When lighting and re-lighting, the gas knob cannot be turned from PILOT to OFF unless the knob is depressed. 1.
  • Page 19: Blower Installation

    BLOWER INSTALLATION 1. Ensure that the access cover plate has been installed. For location, see Figure 30. 2. Remove the on/off switch bracket and the cover plate below it. The switch spacers and cover plate may now be discarded. 3. Decide which side of the blower housing you prefer the on/off switch to be located on.
  • Page 20: Replacements

    Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the follow- ing information: , , , , , FOR WARRANTY WARRANTY WARRANTY WARRANTY...
  • Page 21 W415-0158 / E / 02.19.04 * WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd.
  • Page 22: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED SYMPTOM PROBLEM Pilot will not light. No spark at pilot burner Spark gap is incorrect No gas at the pilot burner Out of propane gas.
  • Page 23 SYMPTOM PROBLEM Main burner goes out; REFER TO "MAIN BURNER GOES OUT; PILOT STAYS ON" pilot goes out. Vent re-circulating (MODEL GDS60 ONLY) Thermocouple shorting or Fireplace is spilling. Exhaust fumes smelled room, headaches. Air shutter has become Carbon is being de- blocked posited on glass, logs or combustion cham-...
  • Page 24 W415-0158 / E / 02.19.04...

This manual is also suitable for:

Gds60-pGs60-pGs60-n