Napoleon GDS60N Installation And Operating Instructions Manual page 52

Vented natural and propane gas fireplace heaters
Table of Contents

Advertisement

52
SYMPTOM
White / grey fi lm
forms.
Flames are very
aggressive.
GDS60 ONLY
Main burner fl ame
is a blue, lazy,
transparent
fl ame.
GDS60 ONLY
Main burner goes
out: pilot goes out.
Main burner and
pilot cycles on
and off.
GS60 ONLY
W415-0788 / B / 11.03.10
PROBLEM
Sulphur from fuel is being
deposited on glass, logs or
combustion chamber
surfaces.
Door is ajar.
Venting action is too great.
Blockage in vent.
Compromised venting.
GLASS EMBERS ONLY:
Too many glass embers.
Vent recirculation.
Venting is spilling.
TEST SOLUTION
-
Clean the glass, see "CARE OF GLASS" section
-
DO NOT CLEAN GLASS WHEN HOT.
-
If deposits are not cleaned off regularly, the glass
may become permanently marked.
-
Tighten door clamps.
-
Restrict vent exit with restrictor plate. See
"RESTRICTING VENTS" section.
-
Remove blockage. In really cold conditions, ice
buildup may occur on the terminal and should be
removed.
-
Check venting system parameters (seal, length,
rise, etc.).
-
Re-distribute glass embers so that only a single
layer is over top of the burner tube.
-
Check joint seals and installation.
-
Test with spill switch bypassed. Replace if defective.
-
Check for vent blockage.
42.7_3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs60nGds60pGs60p

Table of Contents