Top Or Rear Exit Vertical Termination - Napoleon GDS60N Installation And Operating Instructions Manual

Vented natural and propane gas fireplace heaters
Table of Contents

Advertisement

3.11 TOP OR REAR EXIT VERTICAL TERMINATION

Simple venting configurations.
For vent configurations requiring one or more 90° elbows (top exit) or one or more 90° elbows (rear
exit), the following formulas apply:
Formula 1: H
< V
T
Formula 2: H
+ V
T
Example:
V
= 5 FT
1
V
= 6 FT
2
V
= 10 FT
3
V
= V
+ V
+ V
T
1
2
3
H
= 8 FT
1
H
= 2.5 FT
2
H
= H
+ H
= 8 + 2.5 = 10.5 FT
R
1
2
H
= .03 (four 90° elbows - 90°)
O
= .03 (360° - 90°) = 8.1 FT
H
= H
+ H
= 10.5 + 8.1 = 18.6 FT
T
R
O
H
+ V
= 18.6 + 21 = 39.6 FT
T
T
Formula 1:
Formula 2:
Since both formulas are met, this vent configuration is acceptable.
T
< 40 feet
T
= 5 + 6 + 10 = 21 FT
H
< 3.5 V
T
T
18.6 < 21
H
+ V
< 40 FT
T
T
39.6 < 40
(H
) < (V
)
T
T
See graph to determine the required vertical rise V
required horizontal run H
40
30
REQUIRED
VERTICAL
20
RISE IN
FEET V
T
10
3
0
HORIZONTAL VENT RUN PLUS OFFSET IN FEET H
The shaded area within the lines represents acceptable
.
T
5
10
15
values for H
and H
T
T
18.2
W415-0788 / B / 11.03.10
21
for the
T
20
T