Special Vent Installations - Napoleon BGD36CFNTR Installation And Operating Instructions Manual

Napoleon fireplaces gas fireplace installation and operating instructions
Table of Contents

Advertisement

BGD36CF(G)
PERISCOPE TERMINATION
Use the GD201 periscope kit to locate the air termination above
grade. The periscope must be installed so that when fi nal grading
is completed, the bottom air slot is located a minimum of 12" above
grade. The maximum allowable vent length is 10'.
FIGURE 15
TOP EXIT INSTALLATION
BGD42CF
PERISCOPE TERMINATION
Use the GD401 periscope kit to locate the air termination above
grade. The periscope must be installed so that when fi nal grading
is completed, the bottom air slot is located a minimum of 12" above
grade. The maximum allowable vent length is 10'.

SPECIAL VENT INSTALLATIONS

FIGURE 16
REAR EXIT INSTALLATION
FIGURE 17
CORNER TERMINATION
The maximum vent length for a corner installation is 20" of horizontal
run, in addition to the 45° offset. In this case zero rise is acceptable
when using rigid. See FIGURE 18. Flexible venting must maintain a
6" rise. See FIGURE 19.
FIGURE 18
9
FIGURE 19
W415-0661 / C / 02.20.08