BGD36CFG BURNER SWITCH / WIRING DIAGRAM
A wall switch must be installed in a convenient location for the burn-
er operation.
The recommended maximum lead length depends on wire size:
WIRE SIZE
14 gauge
16 gauge
18 gauge
FIGURE 125
N
: W
OTE
IRE TAGS
ARE BRACKETED
B
ATTERY
H
OLDER
AC A
DAPTOR
Main Burner Switch
Brown
(SWI)
Yellow
Red
(+)
Blue
MAX. LENGTH
100 feet
60 feet
40 feet
Black
M
B
S
AIN
URNER
WITCH
(20' R
S
EMOTE
WITCH
W
S
)
IRE
UPPLIED
Red
B
ATTERY
R
ELAY
Red (3 Volt)
B
(12 Volt)
LACK
T
L
&
O
IGHT
S
WITCH
(20' R
EMOTE
W
S
IRE
UPPLIED
M
ODULE
Black
P
LUG
(-)
Black
(TP)
Green x2
(TH)
Black
R
ELAY
P
LUG
A 20' length of millivolt wire is connected to the gas valve for the
burner wall switch. However if a greater length is required route
2-strand (solid core) wire through the electrical hole located at the
bottom left side of the unit.
I
GNITION
M
ODULE
Yellow
(S)
Orange
(I)
*
W
IRE
H
ARNESS
L
TM
IGHT
Orange
S
WITCH
)
Black
Green
Orange x2
(THTP)
P
ILOT
A
SSEMBLY
[through
Gas line
conduit]
[through
independent
conduit]
P
ILOT
G
L
AS
INE
G
V
AS
ALVE
W415-0661 / C / 02.20.08