Specifications (Technical Data); Unpacking The Heater - Bradford White RTG 199 HEN Installation And Operation Instructions Manual

Table of Contents

Advertisement

3.2

Specifications (Technical data)

Approved in US/Canada
Technical characteristics
Capacity
Maximum flow rate at a 45 °F
(25 °C) rise
Maximum flow rate at a 55 °F
(30.6 °C) rise
Maximum flow rate at a 75 °F
(41.7 °C) rise
Maximum flow rate at a 90 °F
(50 °C) rise
Maximum output
Maximum input
Thermal efficiency (Efficiency
in %)
Minimum Input
Temperature Control
Selection range
Default temperature
Stability
Gas Requirement
Gas connection
1)
Peak load inlet gas pressure
Propane
Natural Gas
Water
Hot water connection
Cold water connection
2)
Minimum water flow
Minimum recommended water
pressure
Minimum well pressure
Water valve material
Connections:
Combustion
CO level
CO
level (set from factory)
2
Dimensions
Depth
Width
Height
Weight
Gas types
Natural Gas
Table 3
RTG 199 HE – 6 720 811 617 (2016/01)
Units
RTG 199 H
GPM (l/min)
8.3 (31.4)
GPM (l/min)
6.8 (25.7)
GPM (l/min)
5.0 (18.8)
GPM (l/min)
4.2 (15.7)
BTU/hr (kW)
184,500 (54)
BTU/hr (kW)
199,000 (58.3)
%
> 94%
BTU/hr (kW)
19,900 (5.8)
°F ( °C)
100 - 140 (38 - 60)
°F ( °C)
122 (50)
 2 ( 1)
°F ( °C)
inches
¾ "
water column
8" - 13"
water column
3.5" - 10.5"
inches
¾ "
inches
¾ "
GPM (l/min)
0.5 (1.9)
PSI (bar)
30 (2.07)
PSI
40
Polymer (PPS)
(Polypropylene
Sulfide)
Bottom of heater
 290 (measured)
ppm
%
see table 43
inches (mm)
11 ¼ (286)
7
inches (mm)
17
/
(452)
8
inches (mm)
30½ (775)
pounds (kg)
74 (33.5)
Technical characteristics
LP Gas
Voltage
Nominal
Frequency
Amperage
Idle
Operation
Noise
3)
Water protection
Table 3
1) To measure Gas Pressure, see Measuring Gas Pressure, chapter 4.15, page 33.
2) Activation varies with inlet water temperatures from 0.5 - 1.6 gallon/minute (1.9
- 6.1 l/m).
3) Protection against water drops.
If appliance is installed at elevations above 2000ft, refer
to chapter 4.3.8 Fan speed adjustment.
Safety devices
• Flame failure device (ionization flame rod sensor)
• Overheat prevention (temperature limiter)
• Inlet temperature sensor
• Outlet temperature sensor
• Back flow temperature sensor
• Exhaust gas temperature sensor
3.3

Unpacking the heater

Before installing the unit, be certain you have the correct heater for
your type of Gas - Propane or Natural Gas. Identification labels are
found on the shipping box, and on the rating plate which is located on the
right side panel of the cover.
Fig. 2
Rating plate
[A]
Serial number
[B]
Type of gas
Appliance details
Units
RTG 199 H
V AC
120
Hz
60
mA
40
 2.5
A
db (A)
45 - 65
IP
X4D
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rtg 199 hex