Fig. 65 Reset button
If the problem persists, contact your installer.
6.7

Program button

Fig. 66 "Program" key
6.7.1
Memorizing selected temperature
+
▶ Press buttons
or
to select desired temperature.
▶ Hold "Program" button for 3 seconds to save temperature.
When LCD stops blinking, temperature is saved in memory.
Using "Program" function
In order to select memorized temperature
▶ Press "Program" key.
LCD shows pre-memorized temperature, which is now the hot water
selected temperature.
6.8

Locked condition

This condition is only valid for appliances with one or more remote
controls installed.
Fig. 67 Locked condition
Whenever LCD shows
, the temperature setting cannot be
adjusted because the appliance is in use by a user which already
selected a different temperature. Appliance will be automatically unlock
5 minutes after closing hot water tap.
7

Maintenance and service

DANGER:
▶ Always shut off the electrical power supply, shut off
the manual gas valve and shut off the water valves
whenever servicing.
RTG 199 HE – 6 720 811 617 (2016/01)
6720608920-15. 1 AL
NOTICE:
▶ Inspect and clean the complete water heating system
once a year.
▶ Carry out a maintenance as necessary. Immediately
repair all faults to avoid damage to the system.
Annual maintenance table
1.
Inspect venting system
2.
Inspect combustion chamber
3.
Inspect burner
4.
Inspect condensate trap
5.
Inspect water filter
Table 42 Annual maintenance
7.1

Annual maintenance

(To remove front cover, see page 8.)
Venting System
• Venting system - inspect inside of flue pipe for any blockage or
restriction. Observe burner flames during heater operation. (front
cover must be removed). Inspect the combustion air inlet pipe for
blockage or debris. Inspect combustion air and exhaust terminations
for blockage or debris. Inspect combustion chamber for blockage or
debris.
Combustion Chamber
• Inspect burner observation window (Fig.79, #14, page 51) for
cracks or spillage of flue gases. Observe burner flames during heater
operation. Flames should be steady and blue with no signs of
yellowing. Yellow burner flames are an indication of improper
combustion. Refer to Section 4.4, page 23, chapter 4.3, page 10 of
this manual to verify exhaust system and combustion air supply
meets manufacturer's specifications.
Pressure Relief
• Manually open the pressure relief valve to ensure proper operation.
Inlet Water Filter
• Verify the inlet filter screen is clean and undamaged. The inlet water
filter is located on the bottom of the appliance, to the right of the cold
water inlet fitting. (See Fig.36, page 29). Close installer supplied
water shutoff and remove wireform spring clip from filter. Remove
filter, clean and or replace if damaged.
Descaling
• In areas where the water supply has a high mineral content, the heat
exchanger should be flushed with a descaling solution. Scale build up
will shorten the life of the water heater and damage resulting from
scale is not covered under warranty. Refer to section7.3 for detailed
instructions on descaling the heat exchanger.
Fin Coils
• Inspect heat exchanger fin coils for soot build-up or blockage. If there
is evidence of soot build-up or blockage, the heat exchanger should
be removed by a professional and cleaned thoroughly.
Condensate trap
• Check water level in the condensate trap, see fig. 42, page 31.
• If appliance is out of service for more than 10 days, fill as described
on page 30.
• Check for debris and clean if needed.
Maintenance and service
Every year
X
X
X
X
X
37