Procedures
* Both the service technician and the user can perform all adjustments.
* This adjustment will have an effect only on images stored in the Auto color mode.
Scan to Box
(1) Adjust the threshold value, in order to store black-and-white originals with the appropriate density.
• Use steps (a) to (d) to adjust the threshold value.
(a) Press the [USER FUNCTIONS] button on the Control Panel to enter the "User Functions" menu.
(b) Press the [USER] button.
(c) Press the [SCAN] button.
(d) In the "THRESHOLD" option, press [
• If the threshold value is set to "
• If the threshold value is set to "
After adjusting the threshold value, scan and store the original in the e-Filing box. Then check the image
quality.
Only if the user's desired image quality is still not obtained after the threshold value has been adjusted, use
the next procedure.
* This adjustment will have an effect only on images stored in the Auto color mode.
Scan to Box
(2) Select "HIGH QUALITY" from among the "IMAGE QUALITY FOR BLACK" options, to store the black-
and-white original in the Gray scale mode.
• Use steps (a) to (d) to select the "IMAGE QUALITY FOR BLACK" option.
(a) Press the [USER FUNCTIONS] button on the Control Panel to enter the "User Functions" menu.
(b) Press the [USER] button.
(c) Press the [SCAN] button.
(d) Press the [HIGH QUALITY] button in the "IMAGE QUALITY FOR BLACK" option.
Precautions after the completion of the adjustment
All scanning functions are implemented with reference to the threshold value and the "IMAGE QUALITY FOR
BLACK" option. They will affect the image quality of black-and-white originals stored in the Auto color mode.
Therefore, carefully perform the adjustment, being aware that the image quality of all future images will be
changed, when storing originals other than the one that is used for the adjustment.
Remarks
• If "HIGH QUALITY" is selected from among the "IMAGE QUALITY FOR BLACK" options and black-and-
white originals are scanned in the Auto color mode and stored in the e-Filing box (Scan to Box), this allows
them to be stored in the Gray scale mode rather than in the binary mode, and eventually provides better
halftones. The data will increase in size, compared to those in the binary mode.
• The adjustment of threshold values will be effective, only if "STANDARD" is selected from among the
"IMAGE QUALITY FOR BLACK" options.
] or [
] to adjust the threshold value.
," the original will be stored with the low density.
," the original will be stored with the high density.
4. e-Filing-specific Adjustments