Gas Pressure Testing Procedure; Pilot Adjustment - Pacific energy BROADWAY Installation And Operating Instructions Manual

Direct vent gas insert
Table of Contents

Advertisement

Note: To test the gas pressure, turn off the gas supply to the appliance before loosening test point
screws.
Verify gas pressures with the fireplace lit and at the highest setting.
1. Remove door (Figure 35) and locate the valve as seen in Figure 28.
2. Locate the inlet and outlet test points on the valve which can be seen in Figure 29. After locating test
ports loosen the screws within the ports using a at-tip screwdriver.
3. Attach pressure gauge to the test ports.
4. Turn gas supply back on and test pressures.
5. After testing is nished turn off gas supply, remove the pressure gauges and retighten the screws in the
test points.
Figure 28: Valve location.
The pilot ame level can be adjusted by turning the adjustment screw, using a at-tip screwdriver, seen on the
valve in Figure 29.
Figure 29: Valve.
BDWY.BODYB
230216-44
BRNT.BODYB

Gas Pressure Testing Procedure

Pilot Adjustment