Figure 22: Mantel clearances.
8"
Figure 23: Sidewall clearances.
BDWY.BODYB
230216-44
BRNT.BODYB

Clearances to Combustibles

Minimum hearth depth
As measured from glass
*
Fireplace Surround Fronts located onpage 25.
Fireplace Surrounds and oversize backing plates for larger
fi replace openings located on page 25.
Fronts and Surrounds part numbers located on page 37.
Mantel Clearances
Broadway
A
20 1/2"
B
16"
C
12"

Mantel Depth

D
12"
E
9"
F
6"
*
Note on Hearth distance requirement
Although a 16" hearth is required on the
Brentwood replace, there is no requirement
for a hearth on the Broadway replace.
8"
17
Brentwood
32"
32"
32"
5055.66-B